Emergency
Eyewash Station Inspection Checklist: Weekly Test Form
- Frequency
- Weekly
- Completed by
- Person assigned to check emergency equipment in the area
- Approved by
- Area supervisor
- The checklist
- 28 checks · 5 sections
An eyewash station inspection checklist is the weekly check that an emergency eyewash can be reached in seconds, starts with one movement, runs hands-free from both nozzles and delivers clean water. A person who works in the area can do it in a few minutes per station; a station that fails a critical check is tagged out and reported the same day.
In the United States, OSHA 29 CFR 1910.151(c) requires suitable facilities for quick drenching or flushing of the eyes and body wherever people may be exposed to injurious corrosive materials. It sets no test interval. The weekly activation and the yearly full inspection come from ANSI/ISEA Z358.1, which OSHA has not adopted but treats as guidance. Turkish legislation does not name eyewash stations or set an interval either: employers rely on the general duties to prepare for chemical emergencies and to keep first-aid equipment easy to reach.
This form covers the weekly user check of plumbed and self-contained eyewash and eye/face wash units. It does not replace the annual inspection (flow rate, temperature, installation) or the manufacturer's maintenance instructions. To decide where eyewash stations are needed, start from your chemical safety programme and your first aid needs assessment.
How to use this checklist
- Give every eyewash station a number and check each one once a week, on a fixed day, with one form per station.
- Walk to the station from the place where a splash could happen: check the route, the sign, the lighting and the space around the unit before you touch it.
- For a plumbed unit, open the valve with one movement, let go, and watch the water while it runs for as long as the manufacturer's instructions say. For a self-contained unit, do not empty the tank: check the fluid level and the date instead.
- Mark each check Pass, Fail or N/A and photograph every defect. Wipe up spilled water and put the nozzle covers back.
- If a critical check fails, tag the station out of service, tell the supervisor, and make sure another means of flushing the eyes is within reach before work with hazardous materials goes on.
- Write the date and your initials on the station's tag or log, sign the form and keep it with the emergency equipment records.
The checklist: Eyewash Station Inspection Checklist: Weekly Test Form
Inspection details
Location and access
Walk to the station from the place where a splash could happen.
- 1.
The station can be reached from the hazard in about 10 seconds
ANSI Z358.1, as summarised by CCOHS: an average person walks 16 to 17 m (55 ft) in 10 seconds.
PassFailN/A - 2.
It is on the same floor as the hazard, with no stairs or doors to pass on the way
Ref.: [3]
PassFailN/A - 3.
The route to the station is clear of stored materials, equipment and other obstacles
PassFailN/A - 4.PassFailN/A
- 5.PassFailN/A
- 6.
Nothing is stored in, on or directly around the unit
ANSI Z358.1, as summarised by CCOHS: nozzles at least 15 cm (6 in) from the wall or nearest obstruction and 83.8 to 134.6 cm (33 to 53 in) above the floor.
PassFailN/A
Condition of the unit
Visual checks before the water is turned on.
- 7.PassFailN/A
- 8.PassFailN/A
- 9.PassFailN/A
- 10.
An outdoor or unheated station is protected from freezing
Mark N/A for stations in heated indoor areas.
Ref.: [3]
PassFailN/A - 11.
Self-contained unit: the tank is full and the flushing fluid is within its dateCritical
Change the fluid and clean the tank as the manufacturer's instructions say, using only solutions meant for flushing eyes. Mark N/A for plumbed units.
PassFailN/A - 12.
Eyewash bottles kept at the station are sealed and within their expiry date
Bottles supplement a station; they do not replace it. Mark N/A if there are none.
PassFailN/A
Activation test
Plumbed units: open the valve and let the water run. Self-contained units: follow the manufacturer's instructions and mark N/A where a check would empty the tank.
- 13.PassFailN/A
- 14.PassFailN/A
- 15.
The dust covers come off by the water flow alone
Covers that stay on can be a sign of low flow.
PassFailN/A - 16.PassFailN/A
- 17.PassFailN/A
- 18.
The unit was run long enough to clear the standing water from the supply pipe
Follow the manufacturer's instructions for how long. Stagnant water can carry organisms that infect an injured eye.
PassFailN/A - 19.PassFailN/A
- 20.
The water feels lukewarm, neither hot nor ice-cold
ANSI Z358.1, as summarised by CCOHS, defines tepid as 16 to 38 °C (60 to 100 °F). Temperature is measured at the annual inspection.
PassFailN/A - 21.PassFailN/A
Records and instruction
- 22.
The tag or log shows a full inspection within the last 12 months
Ref.: [3]
PassFailN/A - 23.YesNo
- 24.YesNoN/A
Result
- 25.
Every defect found has been reported to the supervisor and a repair requested
Ref.: [5]
YesNoN/A - 26.
If a critical check failed, the station is tagged out of service and work with hazardous materials in the area does not go on without another means of flushing the eyesCritical
YesNoN/A - 27.YesNo
- 28.
Notes and defects found
Note: ________
Critical check: if it fails, stop and correct it before work continues.
Sign-off
Inspector
Area supervisor
Run this checklist on your phone
FindRisk turns inspections into a few taps: AI-generated checklists you can edit and save as templates, photo markup with AI hazard analysis, Fine-Kinney risk scoring and an instant PDF report.
Download FindRiskLegal basis and references
- [1] United States: OSHA 29 CFR 1910.151, Medical services and first aid — Paragraph (c): suitable facilities for quick drenching or flushing of the eyes and body within the work area for immediate emergency use. Sets no test interval. 29 CFR 1926.50(g) has the same wording for construction.
- [2] United States: OSHA InfoSheet, Health Effects from Contaminated Water in Eyewash Stations (OSHA 3818, 2015) — ANSI performance figures (tepid fluid, 1.5 L/min for 15 minutes, single movement, hands-free); organisms in stagnant water; manufacturer's instructions for how often and how long to activate plumbed units and for maintaining self-contained units. Advisory, not a regulation.
- [3] International: Canadian Centre for Occupational Health and Safety (CCOHS), Emergency Showers and Eyewash Stations (fact sheet, revised 2024-03-15) — Public summary of ANSI/ISEA Z358.1-2014 (R2020): 10-second reach, same level, clear path, sign and lighting, valve operation, flow rates, nozzle height and clearance, covers, tepid range, weekly activation, annual inspection, self-contained units, records, instruction, drainage and freeze protection. The standard itself was not consulted.
- [4] United States: University of Arkansas, Office of Environmental Health and Safety, Emergency Eye/Face Wash Station Weekly Inspection Checklist (revised June 2023) — Institutional weekly practice: sign and lighting, clearance, clear water, even flow from all nozzles, hands-free flow that does not trickle, caps that open on activation, leaks, dated and initialled log.
- [5] International: University of Waterloo Safety Office, Eye/Face Wash and Drench Hose Weekly Inspection (v.1.1, May 2023) — Institutional weekly practice: clear pathway, no leaks, clean unit, flushing stagnant water from the dead leg, hands-free flow, flow pattern; when a problem is found, report it, tag out the station and use no hazardous materials until it is repaired.
- [6] United Kingdom: HSE, Frequently asked questions on first aid — Eye irrigation where mains tap water is not readily available: at least one litre of sterile water or sterile normal saline (0.9%) in sealed, disposable containers, not reused once opened and not used after the expiry date.
- [7] Türkiye: Kimyasal Maddelerle Çalışmalarda Sağlık ve Güvenlik Önlemleri Hakkında Yönetmelik (Resmî Gazete, 12.08.2013, 28733) — Article 8 (emergencies): measures to reduce the effects of chemical emergencies are taken at once and emergency response procedures are kept ready. The regulation does not name eyewash stations.
- [8] Türkiye: İşyeri Bina ve Eklentilerinde Alınacak Sağlık ve Güvenlik Önlemlerine İlişkin Yönetmelik (Resmî Gazete, 17.07.2013, 28710) — Annex 1, item 60: first-aid equipment is kept in easily accessible places wherever working conditions require it. The regulation does not name eyewash stations.
Version 1 · Updated November 20, 2026 · findrisk.net/checklists/eyewash-station-inspection-checklist/
Fill in this checklist on your phone. Scan to download FindRisk: run the checklist, add photos, score risks and share a PDF report in minutes.
Version 1 · Updated November 20, 2026 · findrisk.net/checklists/eyewash-station-inspection-checklist/
Frequently asked questions
How often should eyewash stations be inspected?
ANSI/ISEA Z358.1 calls for plumbed eyewash units to be activated every week and for a complete inspection once a year, as summarised by the Canadian Centre for Occupational Health and Safety. OSHA 1910.151(c) itself sets no interval; it requires suitable flushing facilities to be available for immediate emergency use. Self-contained units are maintained according to the manufacturer's instructions.
How long should you run an eyewash station during the weekly test?
The 2014 edition of ANSI Z358.1 gives no number of minutes: plumbed eyewashes are activated weekly for a period long enough to verify operation and ensure flushing fluid is available. OSHA's InfoSheet on contaminated eyewash water says the manufacturer's instructions state how often and how long to run a given unit. Published university forms range from 30 seconds to about 3 minutes, or until the standing water in the supply pipe is cleared.
Does OSHA require compliance with ANSI Z358.1?
No. OSHA's letters of interpretation state that ANSI Z358.1 was not adopted by OSHA and that OSHA does not enforce it. The enforceable rule is 29 CFR 1910.151(c), which requires suitable facilities for quick drenching or flushing. OSHA describes the ANSI standard as a source of detail on the location, installation and maintenance of eyewash and shower equipment.
What flow rate and water temperature should an eyewash have?
According to OSHA's InfoSheet, the ANSI standard specifies tepid flushing fluid at not less than 1.5 litres per minute (0.4 gpm) for 15 minutes, started by a single movement and then hands-free. The Canadian Centre for Occupational Health and Safety reports that the standard defines tepid as 16–38 °C (60–100 °F) and asks for 11.4 litres per minute for eye/face wash units. Flow rate and temperature are measured at the annual inspection, not in the weekly check.
Can eyewash bottles replace a plumbed eyewash station?
Not under ANSI Z358.1: as CCOHS summarises it, eyewash bottles and personal units supplement plumbed and self-contained stations but cannot replace them. In the UK, HSE's first-aid guidance says that where mains tap water is not readily available for eye irrigation, at least one litre of sterile water or sterile normal saline in sealed, disposable containers should be provided, not reused once opened and not used after the expiry date.