FindRisk Logo
All checklists

Equipment

Welding Equipment Inspection Checklist: Arc and Oxy-Fuel

Frequency
Every shift
Completed by
Welder
Approved by
Supervisor
The checklist
37 checks · 6 sections

A welding equipment inspection checklist is the check a welder makes on the set before striking an arc or lighting a torch. This one covers manual arc welding sets (stick, MIG/MAG and TIG: the machine, its leads, the electrode holder or torch and the return clamp) and portable oxy-fuel sets (cylinders in use, regulators, flashback arresters, hoses and blowpipe). The welder completes it at the start of each shift, and again when a cylinder is changed or the set is reassembled. Equipment that fails a critical check is taken out of use until it has been repaired.

In the United States, OSHA 29 CFR 1910.254(d)(2) requires all connections to an arc welding machine to be checked before starting operations, and 1926.350(f)(3) and (g)(2) require gas hoses and torches to be inspected at the beginning of each working shift, with defective ones removed from service. In Türkiye, Annex III of the Work Equipment Regulation requires operators to check work equipment before each start of work. In Great Britain, HSE guidance says the welder is responsible for daily equipment checks and reporting defects, and that employers should have a programme of regular checks for welding sets.

This pre-use check does not replace the maintenance and testing in the manufacturer's manual, or the periodic examination of the set by a competent person. It also does not cover the job itself: for fire watch, combustibles and permits, use our hot work permit checklist; for the sockets and panels that feed the machine, see the electrical safety inspection checklist.

How to use this checklist

  1. Complete the checklist at the start of each shift, and again when you change a cylinder, reassemble the set or take over a different machine.
  2. Do the checks on the arc welding machine and its leads with the machine switched off and isolated from the supply.
  3. Mark the sections that do not apply N/A: an arc welding set has no gas hoses or torch valves to check, and a gas set has no welding leads.
  4. On a gas set, leak-test every connection with a leak detecting solution after assembly and before lighting up. Never look for a leak with a flame.
  5. If a critical check fails, do not weld: switch off or close the cylinder valves, tag the equipment "Do not use" and tell your supervisor.
  6. Add the checks that the manufacturer's manual lists for the model, and keep the completed form with the equipment records.

The checklist: Welding Equipment Inspection Checklist: Arc and Oxy-Fuel

Inspection details

Site / area: 
Welding set (make, model): 
Equipment ID or serial number: 
Process: 
Job to be done: 
Date and time: 

Arc welding machine and supply (switched off)

  1. 1.

    Casing and covers are in place and undamaged; no terminals or live parts are exposedCritical

    Ref.: [3] [1]

    PassFailN/A
  2. 2.

    The machine is dryCritical

    A machine that has become wet is thoroughly dried and tested before it is used again.

    Ref.: [3]

    PassFailN/A
  3. 3.

    The supply cable and plug are free of cuts, crushing and other damageCritical

    Ref.: [7] [3] [1]

    PassFailN/A
  4. 4.

    The frame or case of the machine is earthed (grounded) and the earth connection is intactCritical

    OSHA exempts engine-driven machines from frame grounding. Pay special attention to portable machines.

    Ref.: [3] [4]

    PassFailN/A
  5. 5.

    A switch for shutting down the machine is on or near it and can be reached

    Ref.: [3] [4]

    PassFailN/A
  6. 6.

    There are no leaks of cooling water, shielding gas or engine fuelCritical

    Ref.: [3]

    PassFailN/A

Welding leads, holder and return clamp

  1. 7.

    The insulation of the welding lead and the return lead is undamaged along the whole length; no bare conductor showsCritical

    Ref.: [3] [4] [7] [1]

    PassFailN/A
  2. 8.

    There is no splice or repair in the welding lead within 3 m (10 ft) of the electrode holderCritical

    This is the US rule (OSHA 1910.254(d)(8), 1926.351(b)(2)).

    Ref.: [3] [4]

    PassFailN/A
  3. 9.

    Cable connectors are clean, undamaged, insulated, rated for the welding current and fully tightenedCritical

    Lengths of cable are joined only with connectors made for the purpose.

    Ref.: [7] [4] [3]

    PassFailN/A
  4. 10.

    The insulation of the electrode holder or welding torch is complete and undamagedCritical

    On an electrode holder, check the handle and the outer surfaces of the jaws.

    Ref.: [7] [4]

    PassFailN/A
  5. 11.

    The return clamp is undamaged and firmly attached to the workpiece, on clean metal close to the weldCritical

    A clamp on rust instead of clean metal has a high resistance and makes stray currents more likely. Clean spatter off magnetic clamps.

    Ref.: [3] [4] [7]

    PassFailN/A
  6. 12.

    The welding current does not return through chains, wire ropes, cranes or hoists, gas or flammable-liquid pipes, electrical conduit or handrailsCritical

    Ref.: [3] [4] [7]

    PassFailN/A
  7. 13.

    Coiled welding cable has been spread out before use

    A coiled cable can overheat and damage its insulation.

    Ref.: [3]

    PassFailN/A
  8. 14.

    There is a place to rest the holder or torch where it cannot touch people, conducting objects or gas cylinders

    Ref.: [3] [4]

    PassFailN/A

Cylinders, regulators and flashback arresters (oxy-fuel set)

  1. 15.

    Cylinders stand upright and are secured to a trolley, wall or other firm support by a chain or strapCritical

    Ref.: [6] [5] [8] [9]

    PassFailN/A
  2. 16.

    Cylinders are out of reach of sparks, hot slag and flame, or shielded from them, and cannot become part of an electric circuitCritical

    Ref.: [5] [6]

    PassFailN/A
  3. 17.

    Cylinder valves, regulators, hoses and fittings are free of oil and greaseCritical

    Oxygen reacts explosively with oil and grease. Do not handle oxygen equipment with oily hands or gloves.

    Ref.: [5] [6] [8] [9] [2]

    PassFailN/A
  4. 18.

    Each regulator is made for the gas and the cylinder pressure it is fitted toCritical

    A regulator for one gas is not interchangeable with another. Check the gas name and pressure rating marked on it.

    Ref.: [5] [8] [9] [2]

    PassFailN/A
  5. 19.

    Regulators, their gauges and their cylinder connections are undamaged and in working orderCritical

    Look at the union nut and seat before fitting the regulator: a faulty seat can leak. A gauge that does not read correctly is a defect.

    Ref.: [6] [5] [9]

    PassFailN/A
  6. 20.

    A flashback arrester is fitted at the regulator outlet on both the oxygen and the fuel gas line, and neither is damagedCritical

    Recommended by HSE and by the Turkish Ministry of Labour's brochure. Replace an arrester that has been dropped or damaged.

    Ref.: [8] [9] [2]

    PassFailN/A
  7. 21.

    Cylinder valves are within reach, and a valve without a handwheel has its key or wrench left on the stem

    The gas must be able to be shut off quickly in an emergency.

    Ref.: [5] [6] [2]

    PassFailN/A

Hoses, torch and leak test (oxy-fuel set)

  1. 22.

    Hoses are free of cuts, cracks, burns and worn places along their whole lengthCritical

    Ref.: [6] [5] [9] [2]

    PassFailN/A
  2. 23.

    The oxygen hose and the fuel gas hose are easy to tell apart, and each is connected to its own gasCritical

    In the UK, HSG139 gives blue for oxygen, red for acetylene and other fuel gases, and orange for LPG.

    Ref.: [6] [9]

    PassFailN/A
  3. 24.

    Hose ends are held by fittings made for the purpose, and no connection is looseCritical

    HSE does not recommend screw-tightened worm-drive (jubilee) clips: they can leak when over- or under-tightened.

    Ref.: [8] [9] [5] [6]

    PassFailN/A
  4. 25.

    Hoses have no taped or improvised repairsCritical

    Where two hoses are taped side by side, OSHA allows tape on no more than 4 inches in every 12 (about 10 cm in 30).

    Ref.: [8] [2] [5]

    PassFailN/A
  5. 26.

    The torch has a non-return valve on both the oxygen and the fuel gas inlet

    Non-return valves reduce the risk of a flashback but do not stop one; they do not replace flashback arresters.

    Ref.: [8] [9]

    PassFailN/A
  6. 27.

    The torch is undamaged, and its valves, hose couplings and tip connection do not leakCritical

    Ref.: [6] [2] [8]

    PassFailN/A
  7. 28.

    The nozzle is the right size for the job, undamaged, and its openings are clear

    A partly blocked nozzle can cause a backfire. Clean it only with tools made for the purpose.

    Ref.: [6] [8] [2]

    PassFailN/A
  8. 29.

    After assembly, every connection has been leak-tested with a leak detecting solution and no leak was foundCritical

    Never test with a flame. HSE says not to use soapy water, or solutions containing grease or oils, on oxygen systems.

    Ref.: [8] [9] [2]

    PassFailN/A
  9. 30.

    A spark lighter is at hand for lighting the torch

    Torches are not lit with matches or from hot work.

    Ref.: [6] [8]

    PassFailN/A

Around the set

  1. 31.

    Cables and hoses are clear of passageways, ladders and stairs, and away from sharp edges, vehicle routes and falling sparks or hot metal

    Ref.: [6] [8] [2]

    PassFailN/A
  2. 32.

    In damp or wet conditions, or on a metal structure, the welder has an insulating mat or dry platform and dry gloves

    Ref.: [7]

    PassFailN/A
  3. 33.

    Where practicable, the arc is screened from other people by non-combustible or flameproof screens

    Ref.: [4]

    PassFailN/A
  4. 34.

    A fire extinguisher is close to the work

    The other fire precautions belong to the hot work permit.

    Ref.: [8]

    PassFailN/A

Result

  1. 35.

    Every defect found has been reported to the supervisor

    Ref.: [4] [3] [7] [1]

    YesNoN/A
  2. 36.

    If a critical check failed, the equipment is tagged "Do not use" and is not used until repaired by a qualified personCritical

    Ref.: [3] [6] [1] [2] [8]

    YesNoN/A
  3. 37.

    Notes and defects found

    Note: ________

Critical check: if it fails, stop and correct it before work continues.

Sign-off

Welder

Name: 
Signature: 
Date: 

Supervisor

Name: 
Signature: 
Date: 

Run this checklist on your phone

FindRisk turns inspections into a few taps: AI-generated checklists you can edit and save as templates, photo markup with AI hazard analysis, Fine-Kinney risk scoring and an instant PDF report.

Download FindRisk

Legal basis and references

  1. [1] Türkiye: İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği (Resmî Gazete, 25.04.2013) — Annex I 2.19 (protection against contact with electricity); Annex III 1.3 to 1.3.2: operator checks before each start of work, visual check and function test, defective equipment taken out of use; Annex III 1.4 (periodic control intervals).
  2. [2] Türkiye: T.C. Çalışma ve Sosyal Güvenlik Bakanlığı, İş Teftiş Kurulu Başkanlığı, Basınçlı Gaz Tüplerinin Güvenli Kullanımı (broşür, İTKB-İSG-B2011003) — Sections on torches, hoses, regulators and flame arresters, and what to do after a leak or flashback (guidance).
  3. [3] United States: OSHA 29 CFR 1910.254, Arc welding and cutting — (b)(4) enclosed controls and terminals; (c)(2) grounding and return circuits; (c)(3)(i) disconnecting switch; (d)(2) to (d)(9): checks before starting operations, leaks, electrode holders, cable splices, defects and damaged cables.
  4. [4] United States: OSHA 29 CFR 1926.351, Arc welding and cutting (construction) — (a) electrode holders; (b) welding cables and connectors; (c) ground returns and machine grounding; (d) unattended holders, power switch, reporting defective equipment; (e) screens.
  5. [5] United States: OSHA 29 CFR 1910.253, Oxygen-fuel gas welding and cutting — (b)(5) use of cylinders: oil and grease, valve keys, distance from sparks, electric circuits, valve end up; (e)(5) hose and hose connections; (e)(6) pressure-reducing regulators.
  6. [6] United States: OSHA 29 CFR 1926.350, Gas welding and cutting (construction) — (a)(7) and (a)(9) cylinders steadied and upright; (b)(1) distance from sparks; (f) hose, inspected at the beginning of each working shift; (g) torches, inspected each shift; (h) regulators and gauges; (i) oil and grease.
  7. [7] United Kingdom: HSE, Safety risks from welding (Electrical hazards) — Guidance on leads, connectors, holders, the current return clamp, damp conditions, and daily equipment checks by the welder.
  8. [8] United Kingdom: HSE, Safety in gas welding, cutting and similar processes, INDG297(rev1) (2012) — Checking for leaks, hose repairs and clips, non-return valves, flashback arresters, what to do after a backfire or flashback, securing cylinders (good practice, not compulsory).
  9. [9] United Kingdom: HSE, The safe use of compressed gases in welding, flame cutting and allied processes, HSG139 (1997) — Paragraph 35 (hose colours); 41 (hose assemblies); 46 and 48 (non-return valves, flame arresters); 63 and 64 (cylinders in use); 75 and 76 (pre-use check, leak test); 97 and 98 (regular examination).

Version 1 · Updated November 20, 2026 · findrisk.net/checklists/welding-equipment-inspection-checklist/

Frequently asked questions

How often should welding equipment be inspected?

At the start of each shift. OSHA 29 CFR 1926.350 requires gas hoses and torches to be inspected at the beginning of each working shift, and 1910.254(d)(2) requires all connections to an arc welding machine to be checked before starting operations. Türkiye's Work Equipment Regulation (Annex III, 1.3) requires an operator check before each start of work. HSE says the welder is responsible for daily equipment checks and that employers should also have a programme of regular checks for welding sets.

Are flashback arrestors required on oxy-fuel welding sets?

HSE's leaflet INDG297 says to fit flashback arresters to both the oxygen and the fuel gas hoses near the regulators, and HSG139 says they should be fitted at the regulator outlet of all acetylene cylinders. The Turkish Ministry of Labour's gas cylinder brochure gives the same advice. These are guidance documents. The OSHA paragraphs on hoses, torches and regulators (1910.253(e)(5) and (e)(6), 1926.350) do not mention flashback arresters for portable cylinder sets; 1910.253(e)(3)(ii) requires protection against backflow and flashback in fuel-gas piping systems.

How do you check a welding gas set for leaks?

HSE's INDG297 says to use a proprietary leak detecting spray or solution suitable for oxy-fuel systems, never a naked flame, and not to use soapy water or solutions containing grease or oils on oxygen systems. HSG139 advises leak testing whenever connections are made, when a leak is suspected by smell or a hissing sound, and after a flashback. Leaking components are repaired or replaced immediately.

Can a damaged welding cable or gas hose be repaired?

OSHA 1910.254(d)(9)(iii) says welding cables with damaged insulation or exposed bare conductors shall be replaced, and (d)(8) bans cables with splices within 10 feet (3 m) of the electrode holder. For gas hoses, OSHA 1926.350(f)(3) requires defective hose to be removed from service. HSE's INDG297 says a leaking hose should not be repaired, but it can be shortened to remove the damaged section, with the hose tail refitted using crimp clips designed for the task.

What should be checked after a flashback?

HSE's INDG297 says to check carefully for damage to the torch, hoses, regulators, flashback arresters and other components, and to replace parts where needed. OSHA 1926.350(f)(4) requires hose that has been subjected to flashback to be tested to twice its normal pressure, and never less than 300 psi, before it is used again. An acetylene cylinder involved in a flashback needs particular attention: if it becomes hot or starts to vibrate, HSE says to evacuate and call the fire service.