Customize & download
Welding Equipment Inspection Checklist: Arc and Oxy-Fuel
Adapt this checklist to your site: edit, add, remove and reorder the checks, add your company name and logo, then save it as a PDF. Nothing is uploaded; your changes stay in this browser.
Your form
Inspection details (blank fields on the form)6 fields
The checklist · 37 checks · 6 sections
Sign-off (who signs the form)2 signers
FindRiskfindrisk.netWelding Equipment Inspection Checklist: Arc and Oxy-Fuel
Inspection details
Arc welding machine and supply (switched off)
- 1.
Casing and covers are in place and undamaged; no terminals or live parts are exposedCritical
Ref.: [3] [1]
PassFailN/A - 2.
The machine is dryCritical
A machine that has become wet is thoroughly dried and tested before it is used again.
Ref.: [3]
PassFailN/A - 3.
The supply cable and plug are free of cuts, crushing and other damageCritical
Ref.: [7] [3] [1]
PassFailN/A - 4.
The frame or case of the machine is earthed (grounded) and the earth connection is intactCritical
OSHA exempts engine-driven machines from frame grounding. Pay special attention to portable machines.
Ref.: [3] [4]
PassFailN/A - 5.
A switch for shutting down the machine is on or near it and can be reached
Ref.: [3] [4]
PassFailN/A - 6.
There are no leaks of cooling water, shielding gas or engine fuelCritical
Ref.: [3]
PassFailN/A
Welding leads, holder and return clamp
- 7.
The insulation of the welding lead and the return lead is undamaged along the whole length; no bare conductor showsCritical
Ref.: [3] [4] [7] [1]
PassFailN/A - 8.
There is no splice or repair in the welding lead within 3 m (10 ft) of the electrode holderCritical
This is the US rule (OSHA 1910.254(d)(8), 1926.351(b)(2)).
Ref.: [3] [4]
PassFailN/A - 9.
Cable connectors are clean, undamaged, insulated, rated for the welding current and fully tightenedCritical
Lengths of cable are joined only with connectors made for the purpose.
Ref.: [7] [4] [3]
PassFailN/A - 10.
The insulation of the electrode holder or welding torch is complete and undamagedCritical
On an electrode holder, check the handle and the outer surfaces of the jaws.
Ref.: [7] [4]
PassFailN/A - 11.
The return clamp is undamaged and firmly attached to the workpiece, on clean metal close to the weldCritical
A clamp on rust instead of clean metal has a high resistance and makes stray currents more likely. Clean spatter off magnetic clamps.
Ref.: [3] [4] [7]
PassFailN/A - 12.
The welding current does not return through chains, wire ropes, cranes or hoists, gas or flammable-liquid pipes, electrical conduit or handrailsCritical
Ref.: [3] [4] [7]
PassFailN/A - 13.
Coiled welding cable has been spread out before use
A coiled cable can overheat and damage its insulation.
Ref.: [3]
PassFailN/A - 14.
There is a place to rest the holder or torch where it cannot touch people, conducting objects or gas cylinders
Ref.: [3] [4]
PassFailN/A
Cylinders, regulators and flashback arresters (oxy-fuel set)
- 15.
Cylinders stand upright and are secured to a trolley, wall or other firm support by a chain or strapCritical
Ref.: [6] [5] [8] [9]
PassFailN/A - 16.
Cylinders are out of reach of sparks, hot slag and flame, or shielded from them, and cannot become part of an electric circuitCritical
Ref.: [5] [6]
PassFailN/A - 17.
Cylinder valves, regulators, hoses and fittings are free of oil and greaseCritical
Oxygen reacts explosively with oil and grease. Do not handle oxygen equipment with oily hands or gloves.
Ref.: [5] [6] [8] [9] [2]
PassFailN/A - 18.
Each regulator is made for the gas and the cylinder pressure it is fitted toCritical
A regulator for one gas is not interchangeable with another. Check the gas name and pressure rating marked on it.
Ref.: [5] [8] [9] [2]
PassFailN/A - 19.
Regulators, their gauges and their cylinder connections are undamaged and in working orderCritical
Look at the union nut and seat before fitting the regulator: a faulty seat can leak. A gauge that does not read correctly is a defect.
Ref.: [6] [5] [9]
PassFailN/A - 20.
A flashback arrester is fitted at the regulator outlet on both the oxygen and the fuel gas line, and neither is damagedCritical
Recommended by HSE and by the Turkish Ministry of Labour's brochure. Replace an arrester that has been dropped or damaged.
Ref.: [8] [9] [2]
PassFailN/A - 21.
Cylinder valves are within reach, and a valve without a handwheel has its key or wrench left on the stem
The gas must be able to be shut off quickly in an emergency.
Ref.: [5] [6] [2]
PassFailN/A
Hoses, torch and leak test (oxy-fuel set)
- 22.
Hoses are free of cuts, cracks, burns and worn places along their whole lengthCritical
Ref.: [6] [5] [9] [2]
PassFailN/A - 23.
The oxygen hose and the fuel gas hose are easy to tell apart, and each is connected to its own gasCritical
In the UK, HSG139 gives blue for oxygen, red for acetylene and other fuel gases, and orange for LPG.
Ref.: [6] [9]
PassFailN/A - 24.
Hose ends are held by fittings made for the purpose, and no connection is looseCritical
HSE does not recommend screw-tightened worm-drive (jubilee) clips: they can leak when over- or under-tightened.
Ref.: [8] [9] [5] [6]
PassFailN/A - 25.
Hoses have no taped or improvised repairsCritical
Where two hoses are taped side by side, OSHA allows tape on no more than 4 inches in every 12 (about 10 cm in 30).
Ref.: [8] [2] [5]
PassFailN/A - 26.
The torch has a non-return valve on both the oxygen and the fuel gas inlet
Non-return valves reduce the risk of a flashback but do not stop one; they do not replace flashback arresters.
Ref.: [8] [9]
PassFailN/A - 27.
The torch is undamaged, and its valves, hose couplings and tip connection do not leakCritical
Ref.: [6] [2] [8]
PassFailN/A - 28.
The nozzle is the right size for the job, undamaged, and its openings are clear
A partly blocked nozzle can cause a backfire. Clean it only with tools made for the purpose.
Ref.: [6] [8] [2]
PassFailN/A - 29.
After assembly, every connection has been leak-tested with a leak detecting solution and no leak was foundCritical
Never test with a flame. HSE says not to use soapy water, or solutions containing grease or oils, on oxygen systems.
Ref.: [8] [9] [2]
PassFailN/A - 30.
A spark lighter is at hand for lighting the torch
Torches are not lit with matches or from hot work.
Ref.: [6] [8]
PassFailN/A
Around the set
- 31.
Cables and hoses are clear of passageways, ladders and stairs, and away from sharp edges, vehicle routes and falling sparks or hot metal
Ref.: [6] [8] [2]
PassFailN/A - 32.
In damp or wet conditions, or on a metal structure, the welder has an insulating mat or dry platform and dry gloves
Ref.: [7]
PassFailN/A - 33.
Where practicable, the arc is screened from other people by non-combustible or flameproof screens
Ref.: [4]
PassFailN/A - 34.
A fire extinguisher is close to the work
The other fire precautions belong to the hot work permit.
Ref.: [8]
PassFailN/A
Result
- 35.
Every defect found has been reported to the supervisor
Ref.: [4] [3] [7] [1]
YesNoN/A - 36.
If a critical check failed, the equipment is tagged "Do not use" and is not used until repaired by a qualified personCritical
Ref.: [3] [6] [1] [2] [8]
YesNoN/A - 37.
Notes and defects found
Note: ________
Critical check: if it fails, stop and correct it before work continues.
Sign-off
Welder
Supervisor
Legal basis and references
- [1] Türkiye: İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği (Resmî Gazete, 25.04.2013) — Annex I 2.19 (protection against contact with electricity); Annex III 1.3 to 1.3.2: operator checks before each start of work, visual check and function test, defective equipment taken out of use; Annex III 1.4 (periodic control intervals).
- [2] Türkiye: T.C. Çalışma ve Sosyal Güvenlik Bakanlığı, İş Teftiş Kurulu Başkanlığı, Basınçlı Gaz Tüplerinin Güvenli Kullanımı (broşür, İTKB-İSG-B2011003) — Sections on torches, hoses, regulators and flame arresters, and what to do after a leak or flashback (guidance).
- [3] United States: OSHA 29 CFR 1910.254, Arc welding and cutting — (b)(4) enclosed controls and terminals; (c)(2) grounding and return circuits; (c)(3)(i) disconnecting switch; (d)(2) to (d)(9): checks before starting operations, leaks, electrode holders, cable splices, defects and damaged cables.
- [4] United States: OSHA 29 CFR 1926.351, Arc welding and cutting (construction) — (a) electrode holders; (b) welding cables and connectors; (c) ground returns and machine grounding; (d) unattended holders, power switch, reporting defective equipment; (e) screens.
- [5] United States: OSHA 29 CFR 1910.253, Oxygen-fuel gas welding and cutting — (b)(5) use of cylinders: oil and grease, valve keys, distance from sparks, electric circuits, valve end up; (e)(5) hose and hose connections; (e)(6) pressure-reducing regulators.
- [6] United States: OSHA 29 CFR 1926.350, Gas welding and cutting (construction) — (a)(7) and (a)(9) cylinders steadied and upright; (b)(1) distance from sparks; (f) hose, inspected at the beginning of each working shift; (g) torches, inspected each shift; (h) regulators and gauges; (i) oil and grease.
- [7] United Kingdom: HSE, Safety risks from welding (Electrical hazards) — Guidance on leads, connectors, holders, the current return clamp, damp conditions, and daily equipment checks by the welder.
- [8] United Kingdom: HSE, Safety in gas welding, cutting and similar processes, INDG297(rev1) (2012) — Checking for leaks, hose repairs and clips, non-return valves, flashback arresters, what to do after a backfire or flashback, securing cylinders (good practice, not compulsory).
- [9] United Kingdom: HSE, The safe use of compressed gases in welding, flame cutting and allied processes, HSG139 (1997) — Paragraph 35 (hose colours); 41 (hose assemblies); 46 and 48 (non-return valves, flame arresters); 63 and 64 (cylinders in use); 75 and 76 (pre-use check, leak test); 97 and 98 (regular examination).
Fill in this checklist on your phone. Scan to download FindRisk: run the checklist, add photos, score risks and share a PDF report in minutes.
This form was customized by its user from a FindRisk template. It is a guide and does not replace a risk assessment or the periodic inspection by a competent person.
Based on the template at: findrisk.net/checklists/welding-equipment-inspection-checklist/ · Version 1