Workplace
Chemical Storage Inspection Checklist: Store and Cabinets
- Frequency
- Weekly
- Completed by
- Person in charge of the chemical store
- Approved by
- Supervisor or safety professional
- The checklist
- 36 checks · 6 sections
A chemical storage inspection checklist is the routine walk-round of a chemical store, drum store or storage cabinet: are the containers labelled, closed and sound, are incompatible chemicals kept apart, would a spill be held, and is the emergency equipment ready. The person in charge of the store completes it; a leaking container, incompatible chemicals stored together or an ignition source near flammables is dealt with at once.
No regulation we could find sets an inspection interval for a chemical store. In the United States, OSHA 29 CFR 1910.106 covers the storage of flammable liquids in containers and cabinets, and 1910.1200 requires labels on containers and safety data sheets that are readily accessible. In the UK, HSE's guidance HSG71 and HSG51 describes good practice for packaged dangerous substances and flammable liquids, and leaves the inspection frequency to the operator. In Türkiye, the Regulation on Health and Safety Measures in Work with Chemical Substances requires arrangements for safe storage, keeping chemicals that can affect each other out of contact, and adequate control of the measures taken. This form is set up as a weekly check; fix your own interval in the risk assessment.
It covers packaged chemicals (bottles, cans, drums, IBCs) in a storeroom, warehouse area, outdoor compound or cabinet. It does not cover bulk tanks or gas cylinders, and it does not replace the COSHH or chemical risk assessment, the explosion protection document or the safety data sheets. For the wider programme, see our guide to chemical safety in the workplace.
How to use this checklist
- Take the chemical inventory and the segregation plan (or the storage sections of the safety data sheets) with you, and use one form per store, compound or group of cabinets.
- Start at the door: check access, signs and lighting before you walk in, then go shelf by shelf, looking at labels, lids and the condition of each container.
- Do not touch or move a container that is leaking, bulging or unlabelled. Keep people away, tell the supervisor and follow the spill procedure and the safety data sheet.
- Mark each check Pass, Fail or N/A and photograph every defect. Mark N/A where a check does not apply, for example the cabinet check in a store with no flammable liquids.
- If a critical check fails, make it safe before you leave: isolate the leak, separate the incompatible chemicals, remove the ignition source.
- Report every defect, sign the form and keep it with the store's records so that the next inspection can check that the defects were closed.
The checklist: Chemical Storage Inspection Checklist: Store and Cabinets
Inspection details
Access, signs and information
Start at the door, before you walk in.
- 1.PassFailN/A
- 2.
Signs at the entrance show the hazards inside and the no-smoking rule, and can be read
PassFailN/A - 3.PassFailN/A
- 4.
An up-to-date inventory lists the chemicals in the store, their quantities and their hazard classes
PassFailN/A - 5.
The safety data sheets for the stored chemicals can be reached from the store without delay
Paper or electronic. In Türkiye the sheets are the Turkish versions provided by the supplier.
PassFailN/A - 6.PassFailN/A
Containers and labels
Go shelf by shelf. Do not touch a leaking, bulging or unlabelled container.
- 7.
Every container has a legible label that names the contents and shows the hazards
PassFailN/A - 8.PassFailN/A
- 9.
There is no unidentified chemical in the storage area
An unidentified chemical is kept apart from the stock until it has been identified or removed.
PassFailN/A - 10.PassFailN/A
- 11.
No container is leaking, bulging, corroded or damagedCritical
Look at drum seams and bases, caps and the shelf or pallet under each container.
PassFailN/A - 12.
Chemicals are in their original packaging or in containers made of a material suited to the contents
PassFailN/A - 13.
No chemical is kept beyond the maximum storage time or expiry date given by the supplier
PassFailN/A
Segregation and stacking
- 14.
Incompatible chemicals are stored apart, as the safety data sheets and the site's segregation plan requireCritical
Examples from HSG71: acids apart from hypochlorites, cyanides, sulphides and alkalis; oxidisers apart from flammables.
PassFailN/A - 15.
Flammable liquids kept in a work area are in a closed, labelled fire-resisting cabinet or bin, within the quantity set for it
HSG51 recommends at most 50 litres of extremely or highly flammable liquids and 250 litres of other flammable liquids with a flashpoint up to 60 °C. OSHA 1910.106(d)(3) allows at most 60 gallons of Category 1 to 3 or 120 gallons of Category 4 liquids in one cabinet. Mark N/A if no flammable liquids are kept.
PassFailN/A - 16.PassFailN/A
- 17.PassFailN/A
- 18.
Stacks are stable and within the height set for the packaging; nothing can slide or fall
Drums lying on their sides are chocked.
PassFailN/A - 19.PassFailN/A
- 20.PassFailN/A
- 21.PassFailN/A
Spill control, ventilation and ignition sources
- 22.
Liquids stand in a bund, on bunded pallets or in drip trays that would hold a spill
HSG71: the bunded volume should be 110% of the single largest receptacle in the bund.
PassFailN/A - 23.
Bunds and trays are empty: no spilled liquid or rainwater takes up their capacity
Ref.: [3]
PassFailN/A - 24.PassFailN/A
- 25.
A spill kit with absorbent suited to the stored chemicals is complete and within reach
PassFailN/A - 26.PassFailN/A
- 27.
There is no smoking, open flame or unauthorised electrical equipment in the store or near flammablesCritical
HSG71 names radios, heaters and kettles as examples of unauthorised electrical equipment, and battery charging as an ignition source.
PassFailN/A - 28.
Empty packaging, pallets, rags and other combustible waste have been removed from the store
PassFailN/A
Emergency equipment and people
- 29.
A fire extinguisher suited to the stored chemicals is in place, easy to reach and within its inspection date
PassFailN/A - 30.
Where corrosives are stored, an eyewash or emergency shower is close by, unobstructed and checked
Mark N/A if no corrosive chemicals are stored.
PassFailN/A - 31.
The gloves, eye protection and other PPE needed for handling and for clearing up a spill are at the store and in good condition
PassFailN/A - 32.
Instructions for a spill or fire and the emergency contact numbers are posted or at hand
PassFailN/A - 33.
People who work in the store have been trained on the hazards, segregation and what to do in a spill
YesNoN/A
Result
Critical check: if it fails, stop and correct it before work continues.
Sign-off
Inspector
Supervisor or safety professional
Run this checklist on your phone
FindRisk turns inspections into a few taps: AI-generated checklists you can edit and save as templates, photo markup with AI hazard analysis, Fine-Kinney risk scoring and an instant PDF report.
Download FindRiskLegal basis and references
- [1] Türkiye: Kimyasal Maddelerle Çalışmalarda Sağlık ve Güvenlik Önlemleri Hakkında Yönetmelik (Resmî Gazete, 12.08.2013, 28733; değişik 20.10.2023, 32345) — Article 7: arrangements for storing hazardous chemicals, keeping chemicals that can affect each other out of contact, minimum quantities, ventilation, no ignition sources, adequate control of the measures. Article 8: emergency information and procedures. Article 9: training, Turkish safety data sheets, labelling. Sets no inspection interval.
- [2] Türkiye: Çalışma ve Sosyal Güvenlik Bakanlığı, İş Sağlığı ve Güvenliği Genel Müdürlüğü, Kimya Sektörü İSG Rehberi (revizyon 2025) — Questions 9 to 13: chemical inventory, safety data sheets kept within easy reach, grouping compatible and incompatible chemicals, minimum conditions for a store (heat and sparks, access, aisles and exits, ventilation and lighting, original labelled packaging, stack height), storage matrix. Guidance, not legislation.
- [3] United Kingdom: HSE, Chemical warehousing: The storage of packaged dangerous substances, HSG71 (Fourth edition, 2009) — Paragraphs 108 to 149 (receipt, marked areas, segregation and chemical incompatibilities, stacking, racking, security, ignition sources), 190 to 211 (ventilation, containers, spill control, 110% bund volume, clean-up and PPE), 243 to 244 (extinguishers). Guidance, not compulsory.
- [4] United Kingdom: HSE, The storage of flammable liquids in containers, HSG51 (Third edition, 2015) — Paragraphs 51 (marking of containers), 87 to 94 (inspection frequencies set by the operator, leaks and damage, stacking, ventilation openings and exits), 113 to 114 (spills), 142 (signs at entrances), 207 to 212 (fire-resisting cabinets, 110% spill retention, recommended 50 and 250 litre maxima).
- [5] United Kingdom: HSE, Offshore COSHH essentials OCM8, Storing chemicals (2011) — Good practice sheet written for offshore installations: restricted access, well lit and ventilated store, defined and signed areas, bunded containers, clear labels, spill kits, daily check for damage and leaks, weekly cleaning, removal of waste packaging, training.
- [6] European Union: Health and Safety Authority (Ireland), Storage of Hazardous Chemicals in Warehouses, Information Sheet (2025) — Good practices: chemical inventory, quarantine of unidentified chemicals, labels and accessible SDSs, regular visual inspections of chemicals and packaging, labels on smaller containers, segregation led by the SDS, secondary containment and spill kits, ignition sources, clear exits, tested emergency equipment, racking.
- [7] United States: OSHA 29 CFR 1910.106, Flammable liquids — Paragraphs (d)(3) (storage cabinets: 60 and 120 gallon limits, label), (d)(5)(i) (exits), (d)(7) (extinguishers, no open flames or smoking, water-reactive materials), (e)(2)(iv)(a) (covered containers), (e)(9) (spills cleaned up promptly, aisles, combustible waste).
- [8] United States: OSHA 29 CFR 1910.1200, Hazard communication — Paragraphs (f)(6) and (f)(9) (each container labelled, tagged or marked; labels not removed or defaced) and (g)(8) (safety data sheets readily accessible during each work shift).
- [9] United States: OSHA 29 CFR 1910.176, Handling materials, general — Paragraphs (b) (containers stored in tiers stacked and limited in height so that they are stable) and (c) (storage areas kept free from accumulated materials that are a fire or tripping hazard).
- [10] United States: OSHA 29 CFR 1910.157, Portable fire extinguishers — Paragraphs (c)(1) (extinguishers mounted, located and identified so that they are readily accessible) and (e)(2) (monthly visual inspection).
- [11] United States: OSHA 29 CFR 1910.151, Medical services and first aid — Paragraph (c): suitable facilities for quick drenching or flushing of the eyes and body within the work area where people may be exposed to injurious corrosive materials.
Version 1 · Updated November 20, 2026 · findrisk.net/checklists/chemical-storage-inspection-checklist/
Fill in this checklist on your phone. Scan to download FindRisk: run the checklist, add photos, score risks and share a PDF report in minutes.
Version 1 · Updated November 20, 2026 · findrisk.net/checklists/chemical-storage-inspection-checklist/
Frequently asked questions
How often should a chemical storage area be inspected?
None of the regulations and guidance behind this checklist sets a fixed interval. Ireland's Health and Safety Authority asks for visual inspections of the chemicals and their packaging on a regular basis, and HSE's HSG51 tells the operator to set the inspection frequencies needed for safe storage. HSE's offshore sheet OCM8 goes further and asks for a check for damage and leaks at least once a day. A weekly walk-round with this form is a reasonable starting point; set the interval in your risk assessment.
Which chemicals should not be stored together?
The safety data sheet is the main source: check its handling and storage section and its stability and reactivity section. HSE's HSG71 gives examples for corrosives: acids with hypochlorites give off chlorine gas, acids with cyanides give off hydrogen cyanide, acids with sulphides give off hydrogen sulphide, and acids with alkalis generate heat. It also warns that oxidising agents greatly increase the severity of a flammable liquid fire, so oxidisers are kept apart from flammables.
How much flammable liquid can be kept in a storage cabinet?
In the United States, OSHA 1910.106(d)(3)(i) allows not more than 60 gallons of Category 1, 2 or 3 flammable liquids, or 120 gallons of Category 4, in one storage cabinet. In the UK, HSE's HSG51 recommends no more than 50 litres of extremely or highly flammable liquids, and no more than 250 litres of other flammable liquids with a flashpoint up to 60 °C, in cabinets or bins in a workroom. HSE describes these as recommended maxima, not absolute limits.
How big should a bund or spill pallet be?
HSE's HSG71 says that in buildings the bunded volume should be 110% of the single largest receptacle in the bund. For outdoor storage it asks for at least 110% of the capacity of the single largest container, except for oil storage, where 25% of the total volume should be used. Rainwater has to be removed so that the bund keeps its capacity.
Do safety data sheets have to be kept in the chemical store?
They have to be within reach of the people who work there. OSHA 1910.1200(g)(8) requires safety data sheets to be readily accessible during each work shift to employees in their work area, and allows electronic access as long as it creates no barrier to immediate access. HSE's HSG71 says safety data sheets detail the action to take for spillages and should be available for all the substances stored on site.
