FindRisk Logo
All checklists

Equipment

Air Compressor Inspection Checklist: Daily Safety Checks

Frequency
Daily
Completed by
Operator or person responsible for the compressor
Approved by
Supervisor
The checklist
35 checks · 6 sections

An air compressor inspection checklist is the daily check an operator makes on a compressor and its air receiver before relying on it for the shift. This one covers stationary and portable workshop or site compressors: where the unit stands, guards, oil and intake filter, the receiver with its safety valve, pressure gauge and drain, a short running check, and the hoses, couplings and blow guns fed from it. The operator or the person responsible for the compressor completes it each day before work starts. If a critical check fails, the compressor is switched off, depressurised and kept out of use until it has been repaired.

In Türkiye, Annex III of the Work Equipment Regulation requires operators to check work equipment before each start of work, and lists compressor air receivers among the pressure vessels that need periodic control at least once a year unless a standard sets another period. In the United States, OSHA 29 CFR 1910.169 requires every air receiver to have a readily visible pressure gauge, a spring-loaded safety valve and a drain valve at its lowest point, and to be drained frequently. In Great Britain, HSE's guidance HSG39 recommends a daily routine check and draining at the end of each day, and the Pressure Systems Safety Regulations 2000 require a written scheme of examination for compressed air systems unless every vessel is below 250 bar litres.

This daily check does not replace the periodic control or statutory examination of the receiver by an authorised or competent person, or the maintenance in the manufacturer's manual. It does not cover breathing air or the pneumatic tools themselves. For the guards on the machines the air drives, see our machine guarding checklist; before any repair, isolate and vent the compressor as described in the lockout tagout guide.

How to use this checklist

  1. Complete the checklist each day before the compressor is put to work, and again when a portable compressor is moved to a new place.
  2. Do the first three sections with the compressor stopped: surroundings, the unit itself, then the receiver and its safety devices.
  3. Start the compressor and watch one full cycle: the pressure on the gauge, the point where it stops or unloads, and any unusual noise or leak.
  4. Walk the hoses from the outlet to each tool or blow gun. Mark checks that do not apply to your compressor N/A.
  5. If a critical check fails, stop the compressor, isolate the power, vent the pressure, tag the unit "Do not use" and tell your supervisor. Never plug, tie down or adjust a safety valve to keep working.
  6. Add the daily checks from the manufacturer's manual for your model, and keep the completed forms with the equipment records.

The checklist: Air Compressor Inspection Checklist: Daily Safety Checks

Inspection details

Site / area: 
Compressor (make, model): 
Equipment ID or serial number: 
Type: 
Maximum pressure marked on the receiver (bar): 
Date of last periodic control / examination: 
Date and time: 

Location and surroundings (compressor stopped)

  1. 1.

    The receiver, its drain valve, safety valve and gauge can be reached; nothing is stored against the unit

    Ref.: [2] [6] [7]

    PassFailN/A
  2. 2.

    The area is well ventilated, and the cooling air inlets and outlets are not obstructed

    Loose equipment or materials in front of the cooler stop the air flow and make the compressor overheat.

    Ref.: [6] [7]

    PassFailN/A
  3. 3.

    The air intake draws from a place free of flammable or corrosive fumes and vapours and of heavy dust

    Look for painting, solvent use or dusty work that has started near the intake since the last check.

    Ref.: [7] [6]

    PassFailN/A
  4. 4.

    The compressor and the floor around it are clean and free of oil deposits and spillage

    Ref.: [6] [7]

    PassFailN/A
  5. 5.

    The unit is protected against being struck by vehicles, materials or equipment

    Ref.: [6] [7]

    PassFailN/A

Compressor unit (stopped)

  1. 6.

    Guards over the belt, pulleys, flywheel and fan are in place, undamaged and firmly fixedCritical

    Ref.: [1] [5] [6]

    PassFailN/A
  2. 7.

    The oil level is between the marks on the dipstick or sight glass

    HSE says any excessive use of lubricating oil should be investigated. Mark N/A on oil-free compressors.

    Ref.: [6] [7]

    PassFailN/A
  3. 8.

    The intake air filter is fitted, undamaged and not clogged

    Ref.: [6]

    PassFailN/A
  4. 9.

    The supply cable, plug and electrical enclosures are undamaged; no conductor or live part is exposedCritical

    Ref.: [1]

    PassFailN/A
  5. 10.

    The stop control and the switch that isolates the power can be seen, identified and reached

    Ref.: [1]

    PassFailN/A
  6. 11.

    The unit, its mountings and pipe connections show no cracks, loose fixings or deformation

    Ref.: [1]

    PassFailN/A

Air receiver and safety devices

  1. 12.

    The receiver shell has no cracks, dents, heavy corrosion or welding added after manufactureCritical

    Look closely at the underside and around the feet and brackets. HSE says brackets are welded to a receiver only to the receiver manufacturer's specification.

    Ref.: [1] [6] [8]

    PassFailN/A
  2. 13.

    The receiver's plate is legible and shows its maximum (safe working) pressure

    In Türkiye, a receiver used below the maximum pressure on its plate is also marked with its operating pressure.

    Ref.: [6] [1] [7]

    PassFailN/A
  3. 14.

    A pressure gauge is fitted on the receiver, is easy to see and read, and is undamagedCritical

    Ref.: [2] [6]

    PassFailN/A
  4. 15.

    A safety valve is fitted on the receiver; it is undamaged, and it is not plugged, tied down or otherwise made inoperativeCritical

    It should discharge to a safe place. HSE recommends easing safety valves by hand each week where the design allows.

    Ref.: [2] [6] [8]

    PassFailN/A
  5. 16.

    The set pressure marked on the safety valve is not higher than the maximum pressure marked on the receiver, and the setting has not been tampered withCritical

    Where an operating pressure has been set for the receiver, the valve matches that value. Only an authorised person changes the setting.

    Ref.: [1] [6] [8]

    PassFailN/A
  6. 17.

    There is no valve of any type between the receiver and its safety valveCritical

    Ref.: [2] [7]

    PassFailN/A
  7. 18.

    The drain valve at the lowest point of the receiver opens, closes tight and is not choked with sediment

    Check an automatic drain with its manual override.

    Ref.: [2] [6]

    PassFailN/A
  8. 19.

    Condensate has been drained from the receiver, the cooler and the water traps

    HSE recommends draining at the end of each day. OSHA requires draining often enough to prevent excessive liquid from accumulating.

    Ref.: [2] [6] [7]

    PassFailN/A
  9. 20.

    The receiver's periodic control or statutory examination is in date, and the report is availableCritical

    Türkiye: at least once a year unless a standard sets another period. Great Britain: as set in the written scheme of examination. A portable compressor used off the premises carries its last report with it in Türkiye.

    Ref.: [1] [8] [7]

    PassFailN/A

Running check

  1. 21.

    The compressor stops or unloads at its set pressure, and the gauge stays at or below the pressure marked on the receiverCritical

    A safety valve that keeps discharging means the system is over-pressurising or the valve is faulty: stop and report it.

    Ref.: [6] [1] [8]

    PassFailN/A
  2. 22.

    The compressor runs without unusual noise or vibration

    Ref.: [6]

    PassFailN/A
  3. 23.

    Where fitted, the oil pressure and outlet air temperature readings are in the manufacturer's normal range and no warning is showing

    Ref.: [6]

    PassFailN/A
  4. 24.

    No air can be heard leaking from the receiver, pipework, fittings or hoses

    Air escaping from the receiver shell or a weld points to a crack: treat it as a failed receiver check and stop.

    Ref.: [6]

    PassFailN/A

Hoses, couplings and blow guns

  1. 25.

    Hoses have no cuts, cracks, bulges or worn places, in particular next to the couplingsCritical

    A hose that ruptures can whip. Replace a damaged hose.

    Ref.: [6] [1]

    PassFailN/A
  2. 26.

    Hoses, fittings and filters are rated for the system pressureCritical

    Compare the working pressure printed on the hose with the pressure at the outlet.

    Ref.: [4] [6]

    PassFailN/A
  3. 27.

    Couplings are undamaged and fully locked, and each tool is secured to its hose so that it cannot come off by accidentCritical

    Ref.: [4] [6]

    PassFailN/A
  4. 28.

    Hoses over 1/2 inch (12.7 mm) inside diameter have a safety device at the supply or branch line that reduces the pressure if the hose fails

    This is the US construction rule (OSHA 1926.302(b)(7)). HSE names hose rupture valves and air fuses as ways to reduce whipping.

    Ref.: [4] [6]

    PassFailN/A
  5. 29.

    Hoses are neatly run and secured, and are not used to pull, lift or lower tools

    Ref.: [6] [4]

    PassFailN/A
  6. 30.

    Air used for cleaning is reduced to less than 30 psi (about 2 bar) at the blow gun, with chip guarding

    This is the US rule (OSHA 1910.242(b)). HSE says a blow gun with a plain reduced orifice is dangerous unless a pre-set, tamper-proof regulator reduces the pressure.

    Ref.: [3] [4] [6]

    PassFailN/A
  7. 31.

    Eye protection is worn where compressed air is used for cleaning

    Ref.: [3] [6]

    PassFailN/A
  8. 32.

    Nobody uses compressed air to clean clothing, hair or skin

    HSE reports very serious and sometimes fatal injuries from this practice and from horseplay.

    Ref.: [6]

    PassFailN/A

Result

  1. 33.

    Every defect found has been recorded and reported to the supervisor

    Ref.: [6] [1]

    YesNoN/A
  2. 34.

    If a critical check failed, the compressor is stopped, isolated, depressurised and tagged "Do not use" until it has been repairedCritical

    Ref.: [1] [8] [6]

    YesNoN/A
  3. 35.

    Notes and defects found

    Note: ________

Critical check: if it fails, stop and correct it before work continues.

Sign-off

Operator

Name: 
Signature: 
Date: 

Supervisor

Name: 
Signature: 
Date: 

Run this checklist on your phone

FindRisk turns inspections into a few taps: AI-generated checklists you can edit and save as templates, photo markup with AI hazard analysis, Fine-Kinney risk scoring and an instant PDF report.

Download FindRisk

Legal basis and references

  1. [1] Türkiye: İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği (Resmî Gazete, 25.04.2013) — Article 7 (periodic control); Annex I 2.3, 2.8, 2.14, 2.19 (stopping, guards, energy isolation, electricity); Annex III 1.3 to 1.3.2 (operator check before each start of work, defective equipment out of use), 1.9, 2.1 and Table 1 (pressure vessels: compressor air receivers, 1 year).
  2. [2] United States: OSHA 29 CFR 1910.169, Air receivers — (b)(1) installation and access; (b)(2) drain valve and draining; (b)(3) pressure gauge, safety valves, no valve between receiver and safety valve, testing of safety valves. 29 CFR 1926.306 repeats these for construction.
  3. [3] United States: OSHA 29 CFR 1910.242, Hand and portable powered tools and equipment, general — (b) compressed air used for cleaning: less than 30 psi, chip guarding and personal protective equipment.
  4. [4] United States: OSHA 29 CFR 1926.302, Power-operated hand tools (construction) — (b) pneumatic power tools: (1) tools secured to the hose; (4) cleaning air; (5) safe operating pressure of hoses and fittings; (6) hoses not used for hoisting; (7) safety device for hoses over 1/2 inch.
  5. [5] United States: OSHA 29 CFR 1910.219, Mechanical power-transmission apparatus — (d)(1) guarding of pulleys; (e) guarding of belt drives.
  6. [6] United Kingdom: HSE, Compressed air safety, HSG39 (second edition, 1998) — Paragraphs 13 (guards); 31 to 45 (air receivers); 48, 64 to 66 (siting, ventilation, intake); 95 to 105 (hoses, couplings, blow guns); 150 to 152 and 162 to 166 (daily, weekly and monthly checks); 173 (training points). Guidance.
  7. [7] United Kingdom: HSE, Safety of pressure systems. Pressure Systems Safety Regulations 2000. Approved Code of Practice and guidance, L122 (second edition, 2014) — Paragraphs 59, 79 and 80 (protective devices, installation, compressed air systems); 115 (examination intervals); 154 (operating instructions for compressed air systems); Schedule 1 (250 bar litre exception).
  8. [8] United Kingdom: HSE, Pressure systems: A brief guide to safety, INDG261(rev2) (2012) — Protective devices, maintenance (signs of wear and corrosion, safety valve repeatedly discharging, depressurise before maintenance) and the written scheme of examination.

Version 1 · Updated November 25, 2026 · findrisk.net/checklists/air-compressor-inspection-checklist/

Frequently asked questions

How often should an air compressor be inspected?

Daily by the user, plus a periodic examination of the receiver. HSE's HSG39 recommends a daily routine check on reciprocating compressors covering oil level, outlet pressure and temperature, unusual noises and draining. Türkiye's Work Equipment Regulation (Annex III, 1.3) requires an operator check before each start of work and a periodic control of compressor air receivers at least once a year unless a standard sets another period. OSHA 1910.169 sets no daily inspection, but requires receivers to be drained frequently and safety valves to be tested frequently and at regular intervals.

How often should an air compressor tank be drained?

HSE's HSG39 says any accumulation of oil and water should be drained from the air receiver, coolers and main supply pipes at the end of each day. OSHA 1910.169(b)(2) does not give a fixed interval: the receiver must be drained frequently and at intervals that prevent excessive liquid from accumulating. Where an automatic drain is fitted, HSG39 says it should have a manual override so that its performance can be checked.

What safety devices must an air receiver have?

OSHA 1910.169 requires an indicating pressure gauge that is readily visible, one or more spring-loaded safety valves, and a drain pipe and valve at the lowest point of the receiver. No valve of any type may be placed between the receiver and its safety valve. HSE's HSG39 adds that the receiver should be clearly marked with its safe working pressure and that the safety valve should let air escape as soon as that pressure is exceeded.

Does a small workshop compressor need a statutory examination in the UK?

It depends on the size of the receiver. Under Schedule 1 of the Pressure Systems Safety Regulations 2000, the written scheme of examination does not apply to a compressed air system if pressure in bar multiplied by internal volume in litres is less than 250 bar litres for each vessel. Above that, a competent person draws up or certifies the scheme and decides the interval. HSE's code of practice L122 notes that air receivers were generally examined every 24 to 48 months under earlier legislation.

Can compressed air be used to clean clothes or work surfaces?

Not clothing or skin: HSE's HSG39 says compressed air should never be used for cleaning clothing, because very serious and sometimes fatal injuries have happened this way. For cleaning work surfaces in the United States, OSHA 1910.242(b) allows compressed air only where it is reduced to less than 30 psi (about 2 bar), and then only with effective chip guarding and personal protective equipment.