FindRisk Logo
All checklists

Equipment

Aerial Lift Pre-Use Inspection Checklist: Boom and Scissor

Frequency
Every shift
Completed by
Platform operator
Approved by
Supervisor
The checklist
42 checks · 6 sections

An aerial lift pre-use inspection checklist is the check the operator completes before using a boom lift or scissor lift each day or shift, and again whenever the operator changes. It covers the documents, a power-off walk-around of the machine, the platform and fall protection, the work zone, and function tests from the ground and platform controls. If a critical check fails, the machine is tagged out of service until it has been repaired.

In Türkiye, Annex III of the Work Equipment Regulation (as amended on 23 December 2025) requires operators to check equipment before each start of work, to inspect it visually, try its functions and record the result; equipment with cracks, excessive wear or similar damage is taken out of use. In the United States, OSHA 29 CFR 1926.453(b)(2)(i) requires lift controls to be tested each day before use, and OSHA's Aerial Lifts fact sheet calls for a pre-start inspection before each work shift. OSHA treats scissor lifts as scaffolds, so under 1926.451(f)(3) a competent person inspects them before each shift. In the UK, HSE expects daily visual checks.

This check does not replace the periodic inspection: in Türkiye an authorised person inspects mobile elevating work platforms to TS EN 280+A1 yearly unless the standards set another interval, and in the UK they need a thorough examination at least every six months. Nor does it replace the manufacturer's inspection list for your model, which takes priority wherever it differs. See our working at height checklist for the rest of the job.

How to use this checklist

  1. Complete the form before the first use of the day or shift and whenever the operator changes, with the manufacturer's manual for this model in hand.
  2. Do the document, walk-around and platform checks with the power off and the platform stowed, then check the work zone at the position where the machine will be used.
  3. Run the function tests with no load in the platform, in an area clear of overhead and ground-level obstructions: first from the ground controls, then from the platform controls.
  4. Mark each check Pass, Fail or N/A (for example outriggers on a machine that has none), and photograph every failed item.
  5. If a critical check fails, do not use the machine: switch it off, remove the key, tag it out of service and report the defect to your supervisor in writing.

The checklist: Aerial Lift Pre-Use Inspection Checklist: Boom and Scissor

Inspection details

Site / work location: 
Machine ID or serial number: 
Machine type: 
Hour meter (h): 
Shift: 
Date and time: 

Documents and operator

  1. 1.

    The operator's manual for this model is on the machine and readable

    Ref.: [12] [1]

    PassFailN/A
  2. 2.

    The latest periodic inspection report is available and has not expiredCritical

    Türkiye: by an authorised person, yearly unless the standards set another interval; the report stays with the machine when it is used off the premises. UK: thorough examination at least every six months. Elsewhere: national rules and the manufacturer's schedule.

    Ref.: [1] [10] [11]

    PassFailN/A
  3. 3.

    The previous form has been read, and every defect it reported has been repaired

    Ref.: [1] [10]

    PassFailN/A
  4. 4.

    The operator is trained and assigned by the employer to use this type of platformCritical

    Ref.: [1] [2] [4] [8]

    PassFailN/A
  5. 5.

    A rescue plan is agreed, and a person on the ground knows the emergency procedure and the ground controlsCritical

    Agree how the people in the platform will communicate with the ground and how they will be brought down if the machine fails.

    Ref.: [10] [1]

    PassFailN/A

Walk-around (power off, platform stowed)

  1. 6.

    Hydraulic oil, engine oil, coolant and fuel are at the correct level

    Mark engine items N/A on battery-powered machines.

    Ref.: [8] [12]

    PassFailN/A
  2. 7.

    There are no oil, fuel or battery fluid leaks on the machine or on the ground beneath itCritical

    Ref.: [8] [12]

    PassFailN/A
  3. 8.

    The battery and charger are undamaged and secure, and the battery is charged

    Ref.: [8] [12] [11]

    PassFailN/A
  4. 9.

    Tyres and wheels have no cuts, worn tread, damage or missing wheel nutsCritical

    Ref.: [8] [12] [3]

    PassFailN/A
  5. 10.

    Hydraulic hoses, cylinders, cables and wiring harnesses are undamaged and not leakingCritical

    Ref.: [8] [12]

    PassFailN/A
  6. 11.

    The chassis, boom or scissor arms and turntable have no dents, cracks or other structural damageCritical

    Look at welds and the metal next to them. Türkiye: a crack or excessive wear takes the machine out of use and calls for a periodic inspection at once.

    Ref.: [1] [12] [8]

    PassFailN/A
  7. 12.

    Pins, locking devices and fasteners are in place and secure, with no loose or missing partsCritical

    Ref.: [8] [12] [1]

    PassFailN/A
  8. 13.

    Outriggers or stabilizers and their pads are undamagedCritical

    Mark N/A if the machine has none.

    Ref.: [8]

    PassFailN/A
  9. 14.

    Safety placards, control markings and the rated load plate are in place and legibleCritical

    The plate gives the maximum load and number of people. Do not use a machine with missing or unreadable placards.

    Ref.: [8] [12] [1] [3]

    PassFailN/A
  10. 15.

    Insulated parts of the boom and bucket are clean and undamaged, with no drilled holes or alterationsCritical

    Mark N/A on machines not sold as insulated.

    Ref.: [8] [4]

    PassFailN/A

Platform and fall protection

  1. 16.

    Guardrails are complete, undamaged and securely fixedCritical

    Ref.: [8] [9] [1] [3]

    PassFailN/A
  2. 17.

    The entry gate closes and latches in place, and its hinges workCritical

    Ref.: [12] [8]

    PassFailN/A
  3. 18.

    The floor is clear of debris, and there are no planks, ladders or boxes to gain extra heightCritical

    Ref.: [4] [8] [12]

    PassFailN/A
  4. 19.

    The manufacturer's lanyard anchor points are undamagedCritical

    Attach only to these points, never to an adjacent structure, pole or other equipment.

    Ref.: [12] [4] [3]

    PassFailN/A
  5. 20.

    Everyone in a boom lift wears a full-body harness with a short lanyard attached to an anchor pointCritical

    Scissor lifts: mark N/A unless the manual or site rules require it. OSHA does not require tie-off on a scissor lift with properly maintained guardrails.

    Ref.: [4] [12] [10] [7]

    PassFailN/A
  6. 21.

    The combined weight of people, tools and materials is within the rated load, and the number of people is within the limitCritical

    Ref.: [4] [8] [1]

    PassFailN/A

Work zone

  1. 22.

    The ground is firm, with no holes, drop-offs, soft fill or unprotected covers along the travel path or at the work positionCritical

    Look for trenches, manholes and uncompacted backfill. Temporary covers must be strong enough for the machine.

    Ref.: [10] [8] [2] [1]

    PassFailN/A
  2. 23.

    The machine stands on level ground or on a slope within the limit given in the manualCritical

    US: wheel chocks on inclines where they can be safely installed.

    Ref.: [4] [9] [12] [2]

    PassFailN/A
  3. 24.

    Outriggers are extended onto pads or a solid surface before the platform is raised, and the brakes are setCritical

    Mark N/A if the machine has none. Use spreader plates if the manual requires them.

    Ref.: [4] [8] [10] [2]

    PassFailN/A
  4. 25.

    Overhead power lines near the work have been identified and the machine can stay clear of themCritical

    OSHA: treat all lines as energized and stay at least 10 ft (3 m) away, more at higher voltages, unless the line owner has de-energized them.

    Ref.: [8] [9] [6] [10]

    PassFailN/A
  5. 26.

    Beams, ceilings and other overhead obstructions have been identified, and the operator knows the crushing riskCritical

    Operators can be pushed against the controls by a fixed structure and be unable to stop the machine.

    Ref.: [10] [8] [9] [1]

    PassFailN/A
  6. 27.

    The area below the platform is barriered or marked, and no one is inside itCritical

    Keep every part of the arm out of traffic routes, and use a ground guide where vehicles pass.

    Ref.: [10] [8] [9] [1]

    PassFailN/A
  7. 28.

    Wind and weather are within the limits in the manual, and the machine is rated for outdoor use if it is outdoorsCritical

    Inspect the platform again after storms or snowfall.

    Ref.: [1] [8] [9] [10] [12]

    PassFailN/A

Function tests (no load in the platform)

  1. 29.

    Every lift function works from the ground controlsCritical

    OSHA 1926.453: on aerial lifts the lower controls must override the upper controls and be plainly marked.

    Ref.: [4] [5] [8] [12]

    PassFailN/A
  2. 30.

    The emergency stop on the ground panel disables all machine functionsCritical

    Ref.: [12] [8] [1] [3]

    PassFailN/A
  3. 31.

    The emergency lowering system or auxiliary power can lower the platformCritical

    Ref.: [12] [1] [10]

    PassFailN/A
  4. 32.

    From the platform, every function works, the console is secure and the levers return to neutralCritical

    Ref.: [4] [8] [12]

    PassFailN/A
  5. 33.

    The emergency stop in the platform disables all machine functionsCritical

    Ref.: [12] [8] [1] [3]

    PassFailN/A
  6. 34.

    All functions stop when the footswitch is released, and the footswitch is not blocked or modifiedCritical

    Mark N/A if the machine uses another enable device, and test that device instead.

    Ref.: [12]

    PassFailN/A
  7. 35.

    Limit and cut-out switches stop their functions, and drive speed drops when the platform is raisedCritical

    Ref.: [12] [3]

    PassFailN/A
  8. 36.

    The tilt indicator or alarm works as described in the manualCritical

    The alarm does not replace checking that the chassis is level.

    Ref.: [12] [3]

    PassFailN/A
  9. 37.

    Overload, anti-entrapment and other safety devices fitted to this machine show no fault and have not been overriddenCritical

    Test them as the manual describes. Mark N/A only for devices this machine does not have.

    Ref.: [8] [12] [10]

    PassFailN/A
  10. 38.

    Steering works, and the brakes stop and hold the machineCritical

    With the platform stowed, test the brakes on a grade within the machine's rated limit.

    Ref.: [8] [9] [12] [1]

    PassFailN/A
  11. 39.

    The horn, gauges, lights and travel or reversing alarm work

    Ref.: [8] [3]

    PassFailN/A

Result

  1. 40.

    Every defect found has been reported in writing to the supervisor

    Ref.: [10] [11] [1]

    YesNoN/A
  2. 41.

    If a critical check failed, the machine is switched off, tagged out of service and not used until repairedCritical

    Ref.: [8] [11] [1] [12]

    YesNoN/A
  3. 42.

    Notes and defects found

    Note: ________

Critical check: if it fails, stop and correct it before work continues.

Sign-off

Operator

Name: 
Signature: 
Date: 

Supervisor

Name: 
Signature: 
Date: 

Run this checklist on your phone

FindRisk turns inspections into a few taps: AI-generated checklists you can edit and save as templates, photo markup with AI hazard analysis, Fine-Kinney risk scoring and an instant PDF report.

Download FindRisk

Legal basis and references

  1. [1] Türkiye: İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği (Resmî Gazete, 25.04.2013; 23.12.2025 değişikliği dahil) — Annex III 1.3–1.3.2 (operator checks before each start of work, visual inspection and function tests, record, taking equipment out of use) and Table 2 (mobile elevating work platforms, yearly unless the standards set another interval, TS EN 280+A1); Art. 7 (periodic inspection, report kept with mobile equipment off the premises); Art. 8 and Annex II 2.1 (trained, assigned operators); Art. 10 (instructions kept with the equipment); Annex I 2.4, 3.1.6, 3.2.2, 3.2.4 (emergency stop, brakes, maximum load marking, people in the carrier: falls, crushing, rescue); Annex II 2.3.1, 3.1.1, 3.1.2.2, 3.1.3, 4.1.1, 4.1.6 (work area, stability, communication and evacuation, collective protection, weather).
  2. [2] Türkiye: Yapı İşlerinde İş Sağlığı ve Güvenliği Yönetmeliği (Resmî Gazete, 05.10.2013, 28786) — Annex 4 (B) items 49–51: equipment kept in working order and used by trained people, periodic checks, ground strength verified and levelling or anchoring done before work starts.
  3. [3] Türkiye: Mustafa Çiçekci, Yükseltilebilir Seyyar İş Platformlarının İş Sağlığı ve Güvenliği Yönünden Değerlendirilmesi (Çalışma Uzmanlık Tezi, ÇSGB) — Table 2.1: control criteria for elevating work platforms (emergency stop, load labels, alarms, wheels, elevated drive speed, lanyard point, guardrails, tilt sensor).
  4. [4] United States: OSHA 29 CFR 1926.453, Aerial lifts — (b)(2): controls tested each day, authorized operators, no belting off to adjacent structures, standing on the floor, lanyard, load limits, brakes, outriggers and chocks, upper and lower controls, insulated portion.
  5. [5] United States: OSHA 29 CFR 1910.67, Vehicle-mounted elevating and rotating work platforms — (c)(2): general industry equivalent of 1926.453(b)(2), cited in the FAQs.
  6. [6] United States: OSHA 29 CFR 1926.451, General requirements (scaffolds) — Applies to scissor lifts: (f)(3) competent person inspection before each shift; (f)(6) power line clearances; (g)(1)(vii) guardrails or fall arrest.
  7. [7] United States: OSHA Standard Interpretation, 1 August 2000, Subpart L: Scissor Lifts — Scissor lifts are not covered by 1926.453 and are treated as scaffolds under 1926.451 and 1926.452(w); no tie-off required with properly maintained guardrails.
  8. [8] United States: OSHA Fact Sheet: Aerial Lifts (DSG 4/2011) — Pre-start inspection before each work shift (vehicle and lift components), work zone inspection, fall protection, loading, overhead protection, stability, tag-out.
  9. [9] United States: OSHA eTool: Scaffolding, Scissor Lifts — Guardrails, stabilization, wind, crushing hazards, 10 ft from power lines, testing controls and brakes before each use.
  10. [10] United Kingdom: HSE, Mobile elevating work platforms (MEWPs) — Daily visual checks, defect reporting, six-monthly thorough examination, trapping, harness and restraint lanyard, rescue plan, ground conditions, weather, barriers below.
  11. [11] International: IPAF, Personel Yükseltici Platformlar İçin Servis, Bakım ve Denetim İlkeleri (TE-2052-0426-1-tr) — Pre-use inspection by the operator, recording recommended; isolate, tag and report defects; types of periodic inspection.
  12. [12] International: JLG, Operation and Safety Manual 3121289 (450A/450AJ Series II) — One manufacturer's example of a pre-start inspection and function check (sections 1, 2 and 4); always use the manual for your model.

Version 1 · Updated November 10, 2026 · findrisk.net/checklists/aerial-work-platform-inspection-checklist/

Frequently asked questions

How often does an aerial lift need to be inspected?

Before each shift or day of use, plus deeper periodic inspections. OSHA 1926.453(b)(2)(i) requires controls to be tested each day before use, and OSHA's fact sheet calls for a pre-start inspection before each work shift. In Türkiye, Annex III of the Work Equipment Regulation requires a check before each start of work and a periodic inspection by an authorised person, yearly unless the standards set another interval. In the UK, HSE requires a thorough examination at least every six months or under an examination scheme.

Who should carry out the pre-use inspection?

The operator who will use the machine. IPAF states that users carry out the pre-use inspection before operating and strongly recommends recording it, and Annex III of Türkiye's Work Equipment Regulation names the operator, or staff who know the equipment and its functions, and requires a record. For scissor lifts in US construction, OSHA's scaffold rule 1926.451(f)(3) gives the pre-shift inspection to a competent person.

Is a scissor lift an aerial lift under OSHA?

No. OSHA's letter of 1 August 2000 says scissor lifts are not covered by the aerial lift rule, 1926.453. They meet the definition of a scaffold, so 1926.451 and the mobile scaffold rules in 1926.452(w) apply. Boom lifts stay under 1926.453 in construction, and OSHA lists 1910.67 for aerial lifts in general industry.

Do you need a harness in a scissor lift?

OSHA's letters of 2000 say tying off is not required on a scissor lift protected by properly maintained guardrails, but the manufacturer's manual or site rules may still require it. On boom lifts, OSHA 1926.453(b)(2)(v) requires a lanyard attached to the boom or basket. HSE says that where a risk of falling remains, the operator wears a harness with a short work restraint lanyard secured to the manufacturer's anchorage point.

At what wind speed should an aerial lift stop working?

Use the limit in the manual for your model, and treat machines rated for indoor use only as unsuitable outdoors. OSHA says not to operate in winds above those the manufacturer recommends and notes that outdoor-rated scissor lifts are generally limited to below 28 mph. One manufacturer's manual, JLG 3121289, gives 28 mph (12.5 m/s). Annex II 4.1.6 of Türkiye's Work Equipment Regulation also puts the manual and production standard first.