{"$schema":"https://findrisk.net/checklists/schema.json","schemaVersion":1,"id":"fire-hose-reel-inspection-checklist","version":1,"date":"2026-11-25T22:03:53+03:00","category":"emergency","industries":["general","manufacturing","warehouse-logistics","healthcare","hospitality","education","retail","office"],"frequency":"monthly","page":{"en":{"slug":"fire-hose-reel-inspection-checklist","title":"Fire Hose Reel Inspection Checklist: Monthly Check Form","description":"Free fire hose reel inspection checklist: access, sign, cabinet, hose, nozzle, valve, leaks and service label, with OSHA 1910.158 and Turkish fire rules.","intro":"A **fire hose reel inspection checklist** is the routine visual check that confirms each hose reel or fire hose cabinet can be seen and reached, holds only firefighting equipment, has an undamaged hose with a shut-off nozzle connected and ready, shows no leaks, and has an in-date maintenance label. A trained member of staff completes one form per cabinet; a unit that fails a critical check is taken out of service and covered by other protection until it is repaired.\n\nIn the United States, OSHA 29 CFR 1910.158(e)(2) requires hose systems to be inspected at least annually and after each use by trained persons the employer designates, and 1910.157(e)(2) requires a monthly visual inspection where hose stations are used in place of portable extinguishers. In Türkiye, Article 94 of the Regulation on the Fire Protection of Buildings makes the periodic maintenance set out in TS EN 671-3 mandatory, and Table 3 in Annex III of the work equipment regulation sets a periodic control at least once a year unless a standard gives another interval. Turkish law sets no monthly interval; workplaces must keep firefighting equipment ready for use, visible and unobstructed at all times, and a monthly check is a common way to show that. Government guidance for England asks for a weekly look that hose reels are correctly located and in apparent working order, and formal maintenance at least annually by a competent person.\n\nThis form is the user check. It does not replace the annual maintenance and periodic control by a competent or authorised person, or any flow and pressure test. To decide where hose reels are needed, start with our [fire risk assessment guide](/blog/fire-risk-assessment-guide); for who does what in a fire, see the [emergency action plan guide](/blog/emergency-action-plan-guide).","howToUse":["Number every hose reel and fire hose cabinet on a floor plan and walk the same route each month, together with the fire extinguisher round.","Fill one form per cabinet: its number and location, the hose type and the date on the maintenance label.","Open the door, swing the reel out and look at the hose, nozzle, valve and connections. Mark each check Pass, Fail or N/A and photograph every defect.","Do not run water during this check unless your site procedure says so; flow and pressure tests belong to the annual maintenance.","If a critical check fails, mark the cabinet out of service, cover the area with extinguishers or a fire watch, and report it for repair the same day.","Write the date and your name on the cabinet's inspection label or log, sign the form and keep it with the fire equipment records."],"faqs":[{"question":"How often should fire hose reels be inspected?","answer":"OSHA 1910.158(e)(2)(iii) requires hose systems to be inspected at least annually and after each use, and 1910.157(e)(2) requires a monthly visual inspection where hose is used in place of portable extinguishers. Government guidance for England lists a weekly check that hose reels are correctly located and in apparent working order, with formal maintenance at least annually by a competent person. In Türkiye, periodic maintenance follows TS EN 671-3 and the periodic control is yearly at most; the law sets no monthly interval, so a monthly check there is good practice."},{"question":"Who can inspect a fire hose reel?","answer":"Under OSHA 1910.158(e)(2)(vi) the employer designates trained persons to carry out the inspections. The guidance for England says you, or a person you have nominated, can do certain routine checks, while formal maintenance is for a competent person. In Türkiye, the yearly periodic control of fire installations is done by authorised mechanical engineers, technicians and the other professions listed in Annex III, 2.3.3 of the work equipment regulation."},{"question":"What should you do if a hose reel fails the inspection?","answer":"OSHA 1910.158(e)(2)(iv) requires a hose system that is found unserviceable to be removed from service immediately and replaced with equivalent protection, such as extinguishers and fire watches. Tag the cabinet, tell the person responsible for fire equipment and have it repaired before it is counted as protection again."},{"question":"What is the difference between a hose reel and a lay-flat hose cabinet?","answer":"The Turkish fire regulation separates them by who will use them. Where no trained people are present, cabinets have a round semi-rigid hose 25 mm in diameter and no longer than 30 m, to TS EN 671-1. Lay-flat hose cabinets to TS EN 671-2, with hose up to 50 mm in diameter and 20 m long, are for buildings that have trained firefighting staff."},{"question":"Which buildings need fire hose cabinets in Türkiye?","answer":"Article 94 of the Regulation on the Fire Protection of Buildings requires them in high buildings, in workshops, factories, warehouses, accommodation, health, assembly and education buildings with more than 1,000 m² of enclosed floor area, in enclosed car parks over 600 m² and in boiler rooms over 350 kW. Cabinets are placed on every floor no more than 30 m apart, or up to 45 m in sprinklered buildings with fire brigade inlets on the floors."}],"tags":["fire hose reel inspection","fire hose cabinet","monthly inspection","OSHA 1910.158","fire safety","emergency equipment"]},"tr":{"slug":"yangin-dolabi-kontrol-formu","title":"Yangın Dolabı Kontrol Formu: Aylık Kontrol Listesi","description":"Ücretsiz yangın dolabı kontrol formu: erişim, işaret, dolap, hortum, lans, vana, sızıntı ve bakım etiketi; Yangın Yönetmeliği Madde 94 dayanağıyla.","intro":"**Yangın dolabı kontrol formu**, her yangın dolabının görünür ve ulaşılır olduğunu, içinde yalnızca söndürme malzemesi bulunduğunu, hortumun hasarsız ve bağlı, lansın yerinde olduğunu, sızıntı olmadığını ve bakım etiketinin güncel olduğunu doğrulayan gözle kontrol içindir. Kontrolü görevlendirilmiş ve bilgilendirilmiş bir çalışan yapar; her dolap için bir form doldurulur. Kritik bir maddeden kalan dolap kullanım dışı olarak işaretlenir ve onarılana kadar o alan başka söndürme imkânlarıyla korunur.\n\nBinaların Yangından Korunması Hakkında Yönetmelik'in 94. maddesi, yangın dolaplarının TS EN 671-3 standardında belirtilen periyodik bakımlarının yaptırılmasını zorunlu tutar; sorumluluk bina sahibi, yöneticisi veya bina sorumlusundadır. İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği Ek-III Tablo-3'e göre yangın dolaplarının periyodik kontrolü, standartlarda süre belirtilmemişse en geç yılda bir yapılır. Mevzuatta aylık bir kullanıcı kontrolü süresi yoktur; ancak İşyeri Bina ve Eklentileri Yönetmeliği söndürme ekipmanının her zaman kullanıma hazır, görünür ve önü açık tutulmasını ister ve aylık kontrol bunu kayıt altına almanın yaygın yoludur. ABD'de OSHA 1910.158 hortum sistemlerinin en az yılda bir ve her kullanımdan sonra kontrol edilmesini ister.\n\nBu form kullanıcı kontrolü içindir; yetkili kişilerce yapılan periyodik kontrolün, standarttaki periyodik bakımın ve debi-basınç testlerinin yerine geçmez. Yangın dolabının nerede gerektiğini belirlemek için [yangın risk değerlendirmesi rehberimize](/blog/fire-risk-assessment-guide), yangın anında kimin ne yapacağı için [acil durum eylem planı rehberimize](/blog/emergency-action-plan-guide) bakabilirsiniz.","howToUse":["Bütün yangın dolaplarını kat planı üzerinde numaralandırın ve her ay aynı güzergâhı, yangın söndürücü kontrolüyle birlikte yürüyün.","Her dolap için bir form doldurun: dolap numarası ve yeri, hortum tipi ve bakım etiketindeki tarih.","Kapağı açın, makarayı dışarı çevirin; hortuma, lansa, vanaya ve bağlantılara bakın. Her maddeyi Uygun, Uygun değil veya Kapsam dışı olarak işaretleyin, uygunsuzlukların fotoğrafını çekin.","İşyeri talimatınız öngörmüyorsa bu kontrolde su akıtmayın; debi ve basınç testleri periyodik bakımın işidir.","Kritik bir madde uygun değilse dolabı kullanım dışı olarak işaretleyin, alanı söndürücü veya gözcü ile koruyun ve aynı gün onarım için bildirin.","Dolabın kontrol etiketine veya kayıt defterine tarihi ve adınızı yazın, formu imzalayın ve yangın ekipmanı kayıtlarıyla birlikte saklayın."],"faqs":[{"question":"Yangın dolabı periyodik kontrolü ne sıklıkla yapılır?","answer":"İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği Ek-III Tablo-3'e göre yangın dolaplarının periyodik kontrolü, standartlarda süre belirtilmemişse en geç yılda bir yapılır. Binaların Yangından Korunması Hakkında Yönetmelik Madde 94 ayrıca TS EN 671-3'te belirtilen periyodik bakımları zorunlu tutar. Mevzuat aylık bir süre belirlemez; aylık gözle kontrol, ekipmanı her zaman kullanıma hazır tutmak için yaygın bir uygulamadır."},{"question":"Yangın dolabı kontrolünü kim yapar?","answer":"Aylık gözle kontrolü görevlendirilmiş ve bilgilendirilmiş bir çalışan yapabilir. Yıllık periyodik kontrol ise yetkili makine mühendisleri, makine teknikerleri ve İş Ekipmanları Yönetmeliği Ek-III madde 2.3.3'te sayılan diğer meslek mensuplarınca yapılır. Periyodik bakımların yaptırılmasından bina sahibi, yöneticisi veya bina sorumlusu sorumludur."},{"question":"Yangın dolabı hortumu kaç metre olmalı?","answer":"Yönetmeliğin 94. maddesine göre eğitimli personeli bulunmayan binalardaki yuvarlak yarı-sert hortumlu dolaplarda hortum çapı 25 mm'dir ve uzunluğu 30 m'yi aşamaz. Yangınla mücadele eğitimi almış personeli olan binalarda kullanılan yassı hortumlu dolaplarda hortum çapı en fazla 50 mm, uzunluğu en fazla 20 m'dir. Her iki tipte de lans kapama, püskürtme, fıskiye veya üçünü birden yapabilmelidir."},{"question":"Hangi binalarda yangın dolabı zorunlu?","answer":"Madde 94'e göre yüksek binalarda, toplam kapalı kullanım alanı 1000 m²'den büyük imalathane, atölye, depo, konaklama, sağlık, toplanma ve eğitim binalarında, alanlarının toplamı 600 m²'den büyük kapalı otoparklarda ve 350 kW'ın üzerindeki kazan dairelerinde yangın dolabı yapılır. Dolaplar her katta, aralarındaki uzaklık 30 m'yi geçmeyecek şekilde yerleştirilir; yağmurlama sistemi ve itfaiye su alma ağzı olan binalarda bu mesafe 45 m'ye çıkabilir."},{"question":"Yangın dolabının önüne veya içine malzeme konabilir mi?","answer":"Hayır. İşyeri Bina ve Eklentileri Yönetmeliği Ek-1 madde 12, yangın söndürme ekipmanlarının önünde engel bulundurulmamasını ister. Binaların Yangından Korunması Hakkında Yönetmelik de yangın musluklarının önünün kapatılmasını yasaklar ve hortum dolabının yalnızca yangın söndürme amacıyla kullanılmasını şart koşar."}],"tags":["yangın dolabı kontrolü","yangın dolabı kontrol formu","yangın hortumu","aylık kontrol","yangın güvenliği","acil durum ekipmanı"]}},"roles":{"completedBy":{"en":"Person assigned to check fire equipment","tr":"Yangın ekipmanı kontrolüyle görevlendirilen kişi"},"approvedBy":{"en":"Facility manager","tr":"Bina / tesis yöneticisi"}},"header":[{"id":"site","label":{"en":"Site / building","tr":"İşyeri / bina"},"type":"text"},{"id":"cabinet-id","label":{"en":"Cabinet number and location","tr":"Dolap no ve yeri"},"type":"text"},{"id":"hose-type","label":{"en":"Hose type","tr":"Hortum tipi"},"type":"select","options":[{"id":"semi-rigid-reel","label":{"en":"Reel with semi-rigid hose","tr":"Yuvarlak yarı-sert hortumlu (makaralı)"}},{"id":"lay-flat","label":{"en":"Lay-flat hose","tr":"Yassı hortumlu"}},{"id":"other","label":{"en":"Other","tr":"Diğer"}}]},{"id":"hose-length","label":{"en":"Hose length","tr":"Hortum uzunluğu"},"type":"number","unit":"m","required":false},{"id":"last-maintenance","label":{"en":"Date on the maintenance label","tr":"Bakım etiketindeki tarih"},"type":"date","required":false},{"id":"inspected-at","label":{"en":"Date and time","tr":"Tarih ve saat"},"type":"datetime"}],"sections":[{"id":"location-access","title":{"en":"Location, access and cabinet","tr":"Yer, erişim ve dolap"},"items":[{"id":"visible-in-place","text":{"en":"The cabinet is in its designated place and easy to see from the corridor or work area","tr":"Dolap belirlenen yerinde ve koridordan veya çalışma alanından kolayca görülüyor"},"response":"pass-fail-na","refs":["bykhy","isyeri-bina","uk-fsra"]},{"id":"unobstructed","text":{"en":"Nothing stands in front of the cabinet or blocks its door","tr":"Dolabın önünde erişimi veya kapağın açılmasını engelleyen bir şey yok"},"guidance":{"en":"Typical defects: pallets, bins, furniture, parked trolleys or stock in front of the door.","tr":"Sık görülenler: kapağın önüne konmuş palet, çöp kovası, mobilya, araba veya malzeme."},"response":"pass-fail-na","critical":true,"photo":"required-on-fail","refs":["isyeri-bina","bykhy","osha-1910-158"]},{"id":"sign","text":{"en":"The cabinet is marked with a permanent, visible fire hose sign","tr":"Dolap kalıcı ve görünür bir yangın hortumu işaretiyle gösterilmiş"},"response":"pass-fail-na","photo":"required-on-fail","refs":["isyeri-bina","osha-1910-158","uk-fsra"]},{"id":"door-opens","text":{"en":"The door opens fully and easily, without a key or tool","tr":"Kapak anahtar veya alet gerekmeden tam ve kolayca açılıyor"},"guidance":{"en":"The cabinet must not slow down the use of the hose in a fire. A jammed, locked or painted-shut door fails.","tr":"Dolap, yangın anında hortumun kullanılmasını güçleştirmemelidir. Sıkışmış, kilitli veya boyayla yapışmış kapak uygun değildir."},"response":"pass-fail-na","critical":true,"photo":"required-on-fail","refs":["bykhy","osha-1910-158"]},{"id":"fire-equipment-only","text":{"en":"The cabinet holds only firefighting equipment","tr":"Dolabın içinde yalnızca yangın söndürme malzemesi var"},"guidance":{"en":"Remove cleaning materials, tools, personal items and rubbish.","tr":"Temizlik malzemesi, alet, kişisel eşya ve çöp dolaptan çıkarılır."},"response":"pass-fail-na","photo":"required-on-fail","refs":["bykhy","osha-1910-158"]},{"id":"cabinet-condition","text":{"en":"The cabinet body, door, glass and hinges show no damage or corrosion","tr":"Dolap gövdesi, kapağı, camı ve menteşelerinde hasar veya korozyon yok"},"response":"pass-fail-na","photo":"required-on-fail","refs":["uk-fsra","osha-1910-158"]}]},{"id":"hose-reel-nozzle","title":{"en":"Hose, reel, nozzle and valve","tr":"Hortum, makara, lans ve vana"},"items":[{"id":"hose-connected","text":{"en":"The hose is connected to the water supply and ready for use","tr":"Hortum su tesisatına bağlı ve kullanıma hazır"},"response":"pass-fail-na","critical":true,"photo":"required-on-fail","refs":["osha-1910-158","bykhy"]},{"id":"hose-condition","text":{"en":"The hose shows no cuts, cracks, kinks, flattening or abrasion along its visible length","tr":"Hortumun görünen boyunda kesik, çatlak, kırılma, ezilme veya aşınma yok"},"response":"pass-fail-na","critical":true,"photo":"required-on-fail","refs":["uk-fsra","osha-1910-158"]},{"id":"hose-stowed","text":{"en":"The hose is wound evenly on the reel or folded properly on its rack, and has been put back in order after its last use","tr":"Hortum makaraya düzgün sarılmış veya askısına düzgün katlanmış; son kullanımdan sonra düzenli şekilde yerine konmuş"},"response":"pass-fail-na","refs":["osha-1910-158"]},{"id":"reel-moves","text":{"en":"The reel swings out of the cabinet and turns freely","tr":"Makara dolaptan dışarı rahatça dönüyor ve serbestçe çevriliyor"},"guidance":{"en":"Mark N/A for lay-flat hose on a rack or cradle.","tr":"Askıya veya sepete katlanmış yassı hortumda Kapsam dışı işaretleyin."},"response":"pass-fail-na","photo":"required-on-fail","refs":["bykhy","osha-1910-158"]},{"id":"nozzle","text":{"en":"A shut-off nozzle is fitted to the hose, undamaged, and its control moves freely","tr":"Hortumun ucunda kapatılabilir lans takılı, hasarsız ve kumandası rahat dönüyor"},"guidance":{"en":"Türkiye: the nozzle must provide shut-off, spray, jet, or all three.","tr":"Lans kapama, püskürtme, fıskiye veya üçünü birden yapabilmelidir."},"response":"pass-fail-na","critical":true,"photo":"required-on-fail","refs":["bykhy","osha-1910-158"]},{"id":"valve","text":{"en":"The cabinet valve has its handwheel or lever, is undamaged and can be reached and operated easily","tr":"Dolap vanasının volanı veya kolu yerinde, vana hasarsız, kolayca ulaşılıyor ve çevrilebiliyor"},"response":"pass-fail-na","critical":true,"photo":"required-on-fail","refs":["osha-1910-158"]},{"id":"no-leaks","text":{"en":"There is no leak or drip at the valve, connections, reel or hose, and no water in the bottom of the cabinet","tr":"Vanada, bağlantılarda, makarada veya hortumda sızıntı ya da damlama yok; dolap tabanında su birikmemiş"},"response":"pass-fail-na","photo":"required-on-fail","refs":["uk-fsra"]},{"id":"instructions","text":{"en":"The operating instructions on or beside the cabinet are in place and legible","tr":"Dolabın üzerindeki veya yanındaki kullanma talimatı yerinde ve okunaklı"},"response":"pass-fail-na","photo":"required-on-fail","refs":["uk-fsra"]}]},{"id":"supply-maintenance","title":{"en":"Water supply, maintenance and users","tr":"Su beslemesi, bakım ve kullanıcılar"},"items":[{"id":"supply-valve-open","text":{"en":"The isolating valve on the pipe feeding the cabinet is fully open","tr":"Dolabı besleyen hattaki kesme vanası tam açık"},"guidance":{"en":"Mark N/A if there is no isolating valve you can see or reach on this route.","tr":"Güzergâhta görebildiğiniz veya ulaşabildiğiniz bir kesme vanası yoksa Kapsam dışı işaretleyin."},"response":"pass-fail-na","critical":true,"refs":["osha-1910-158"]},{"id":"pressure-gauge","text":{"en":"Where a pressure gauge is fitted, it reads within the range given in the system design","tr":"Manometre varsa, gösterdiği basınç tesisat projesinde verilen aralıkta"},"guidance":{"en":"Türkiye: the design pressure at the cabinet is 400 kPa (at least 400 kPa for lay-flat hose), and pressure reducers are required where the nozzle inlet pressure would exceed 900 kPa. Mark N/A if there is no gauge.","tr":"Yuvarlak yarı-sert hortumlu dolaplarda tasarım basıncı 400 kPa, yassı hortumlu dolaplarda en az 400 kPa'dır; lans girişinde basınç 900 kPa'ı geçiyorsa basınç düşürücü kullanılır. Manometre yoksa Kapsam dışı işaretleyin."},"response":"pass-fail-na","photo":"required-on-fail","refs":["bykhy","osha-1910-158","is-ekipmanlari"]},{"id":"cabinet-type","text":{"en":"The hose type suits the people expected to use it","tr":"Hortum tipi, dolabı kullanması beklenen kişilere uygun"},"guidance":{"en":"Türkiye: where there are no trained people, a round semi-rigid hose of 25 mm, no longer than 30 m. Lay-flat hose (up to 50 mm, no longer than 20 m) only where trained firefighting staff are present.","tr":"Eğitimli personel yoksa 25 mm çapında, 30 m'yi aşmayan yuvarlak yarı-sert hortum. Yassı hortum (en fazla 50 mm çap, en fazla 20 m) yalnızca yangınla mücadele eğitimi almış personelin bulunduğu binalarda."},"response":"pass-fail-na","refs":["bykhy"]},{"id":"maintenance-label","text":{"en":"The label or record shows periodic maintenance within the last 12 months","tr":"Etiket veya kayıt, son 12 ay içinde periyodik bakım ve kontrol yapıldığını gösteriyor"},"guidance":{"en":"Türkiye: maintenance as set out in TS EN 671-3; periodic control at least yearly unless the standard sets another interval. OSHA: inspection at least annually and after each use.","tr":"Periyodik bakım TS EN 671-3'e göre yaptırılır; periyodik kontrol, standartlarda süre belirtilmemişse en geç yılda bir yetkili kişilerce yapılır."},"response":"pass-fail-na","photo":"required-on-fail","refs":["bykhy","is-ekipmanlari","ts-en-671-3","osha-1910-158","uk-fsra"]},{"id":"users-trained","text":{"en":"Staff expected to use this hose reel have been trained to use it","tr":"Bu dolabı kullanması beklenen çalışanlar kullanımı konusunda eğitilmiş"},"guidance":{"en":"OSHA: at least annual training where hose stations replace portable extinguishers.","tr":"İngiltere rehberi, dolabı kullanması beklenen çalışanlara uygun eğitim verilmesini ister; OSHA, hortum söndürücülerin yerine kullanılıyorsa en az yılda bir eğitim şartı koyar."},"response":"yes-no-na","refs":["uk-fsra","osha-1910-157"]}]},{"id":"result","title":{"en":"Result","tr":"Sonuç"},"items":[{"id":"defects-reported","text":{"en":"Every defect found has been reported to the person responsible for fire equipment","tr":"Tespit edilen her uygunsuzluk yangın ekipmanından sorumlu kişiye bildirildi"},"response":"yes-no-na","refs":["bykhy","osha-1910-158"]},{"id":"out-of-service","text":{"en":"If a critical check failed, the cabinet is marked out of service and the area is covered by equivalent protection until it is repaired","tr":"Kritik bir madde uygun değilse dolap kullanım dışı olarak işaretlendi ve onarılana kadar alan eşdeğer bir önlemle korunuyor"},"guidance":{"en":"OSHA names extinguishers and fire watches as equivalent protection.","tr":"Örneğin ek yangın söndürücü ve yangın gözcüsü."},"response":"yes-no-na","critical":true,"refs":["osha-1910-158"]},{"id":"record-updated","text":{"en":"The inspection date and the inspector's name are recorded on the cabinet label or in the log","tr":"Kontrol tarihi ve kontrol edenin adı dolap etiketine veya kayıt defterine işlendi"},"response":"yes-no","refs":["uk-fsra"]},{"id":"ready-for-use","text":{"en":"The hose reel is ready for use","tr":"Yangın dolabı kullanıma hazır"},"response":"yes-no","critical":true,"refs":["isyeri-bina","osha-1910-158"]},{"id":"notes","text":{"en":"Notes and defects found","tr":"Notlar ve tespit edilen uygunsuzluklar"},"response":"text","required":false}]}],"signOff":[{"role":{"en":"Inspector","tr":"Kontrolü yapan"}},{"role":{"en":"Facility manager","tr":"Bina / tesis yöneticisi"}}],"references":[{"id":"bykhy","jurisdiction":"TR","title":"Binaların Yangından Korunması Hakkında Yönetmelik (Resmî Gazete, 19.12.2007, 26735)","url":"https://www.mevzuat.gov.tr/mevzuat?MevzuatNo=200712937&MevzuatTur=21&MevzuatTertip=5","note":{"en":"Article 94 (fire hose cabinets: where required, 30 m spacing, placement where easily seen, use only for firefighting, hose types and lengths, nozzle, design pressure, periodic maintenance under TS EN 671-3), Article 100 (owner's or manager's responsibility for periodic checks, tests and maintenance) and Article 7(10) (no blocking or misuse of fire equipment).","tr":"Madde 94 (yangın dolapları: zorunlu olduğu binalar, 30 m aralık, kolayca görülebilecek yerleşim, yalnızca yangın söndürme amacıyla kullanım, hortum tipleri ve uzunlukları, lans, tasarım basıncı, TS EN 671-3'e göre periyodik bakım), Madde 100 (periyodik kontrol, test ve bakımda bina sahibi veya yöneticisinin sorumluluğu) ve Madde 7(10) (yangın musluklarının önünün kapatılmaması, amacı dışında kullanılmaması)."}},{"id":"is-ekipmanlari","jurisdiction":"TR","title":"İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği (Resmî Gazete, 25.04.2013, 28628)","url":"https://www.mevzuat.gov.tr/MevzuatMetin/yonetmelik/7.5.18318.pdf","note":{"en":"Annex III, 2.3.1 (installations: periodic control yearly unless standards say otherwise), 2.3.3 (persons authorised to do it), 2.3.5 (control against the project and the fire regulation) and Table 3 (fire extinguishing systems, including fire hose cabinets).","tr":"Ek-III md. 2.3.1 (tesisatların periyodik kontrolü, standartlarda aksi belirtilmedikçe yılda bir), 2.3.3 (periyodik kontrolü yapmaya yetkili kişiler), 2.3.5 (projeye ve yangın yönetmeliğine uygunluk) ve Tablo-3 (yangın söndürme sistemleri, yangın dolapları dâhil)."}},{"id":"isyeri-bina","jurisdiction":"TR","title":"İşyeri Bina ve Eklentilerinde Alınacak Sağlık ve Güvenlik Önlemlerine İlişkin Yönetmelik (Resmî Gazete, 17.07.2013, 28710)","url":"https://www.resmigazete.gov.tr/eskiler/2013/07/20130717-2.htm","note":{"en":"Annex 1, item 12 (extinguishing equipment always ready for use, maintained, visible, easy to reach and unobstructed) and item 13 (marking with permanent, visible signs).","tr":"Ek-1 md. 12 (söndürme ekipmanının her zaman kullanıma hazır, bakımlı, görünür, kolay erişilir ve önü açık olması) ve md. 13 (kalıcı ve görünür işaretleme)."}},{"id":"osha-1910-158","jurisdiction":"US","title":"OSHA 29 CFR 1910.158, Standpipe and hose systems","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.158","note":{"en":"(c)(1) reels and cabinets: prompt use, conspicuously identified, fire equipment only; (c)(2)(i) accessible outlets; (c)(3)(i) hose connected and ready; (c)(4) shut-off nozzles; (e)(2)(i)–(ii) water supply and open valves; (e)(2)(iii) inspection at least annually and after each use; (e)(2)(iv) unserviceable systems removed from service and replaced with equivalent protection; (e)(2)(vi) trained persons.","tr":"(c)(1) makara ve dolaplar: hızlı kullanım, belirgin işaretleme, yalnızca yangın ekipmanı; (c)(2)(i) erişilebilir çıkışlar; (c)(3)(i) hortum bağlı ve kullanıma hazır; (c)(4) kapatılabilir lans; (e)(2)(i)–(ii) su beslemesi ve açık vanalar; (e)(2)(iii) en az yılda bir ve her kullanımdan sonra kontrol; (e)(2)(iv) kullanılamaz sistemin hizmetten alınması ve eşdeğer koruma; (e)(2)(vi) eğitimli kişiler."}},{"id":"osha-1910-157","jurisdiction":"US","title":"OSHA 29 CFR 1910.157, Portable fire extinguishers","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.157","note":{"en":"(d)(3) hose stations used in place of Class A extinguishers, with at least annual training; (e)(2) monthly visual inspection of extinguishers or of hose used in their place.","tr":"(d)(3) A sınıfı söndürücülerin yerine kullanılan hortum istasyonları ve en az yıllık eğitim; (e)(2) söndürücülerin veya onların yerine kullanılan hortumun aylık gözle kontrolü."}},{"id":"uk-fsra","jurisdiction":"UK","title":"HM Government, Fire safety risk assessment: offices and shops (updated 12 September 2023)","url":"https://www.gov.uk/government/publications/fire-safety-risk-assessment-offices-and-shops/fire-safety-risk-assessment-offices-and-shops-accessible","note":{"en":"Part 1, 3.4.2 and 3.4.6 (weekly check that hose reels are correctly located and in apparent working order); Part 2, 3.2 (visual checks for leaks and obvious damage, formal maintenance at least annually by a competent person, training); 3.4.5 and section 6 (signs); 7.1 (records). Guidance for England under the Regulatory Reform (Fire Safety) Order 2005.","tr":"Bölüm 1, 3.4.2 ve 3.4.6 (hortum makaralarının yerinde ve çalışır görünümde olduğunun haftalık kontrolü); Bölüm 2, 3.2 (sızıntı ve belirgin hasar için gözle kontrol, en az yılda bir yetkin kişi tarafından bakım, eğitim); 3.4.5 ve bölüm 6 (işaretler); 7.1 (kayıtlar). İngiltere için rehber niteliğindedir."}},{"id":"ts-en-671-3","jurisdiction":"EU","title":"EN 671-3, Fixed firefighting systems — Hose systems — Part 3: Maintenance of hose reels with semi-rigid hose and hose systems with lay-flat hose (TS EN 671-3)","url":"https://standards.iteh.ai/catalog/standards/cen/557d0f7d-0d32-499c-a9a4-a56398d6aab3/en-671-3-2000","note":{"en":"The standard named by Article 94 of the Turkish fire regulation and by the guidance for England for the maintenance of hose reels (title only).","tr":"Binaların Yangından Korunması Hakkında Yönetmelik Madde 94'te periyodik bakım için atıf yapılan standart (yalnızca başlık)."}}],"relatedPosts":["fire-risk-assessment-guide","emergency-action-plan-guide"]}